Coronary artery calcium scoring using ECG-gated multidetector CT: effect of individually optimized image-reconstruction windows on image quality and measurement reproducibility



Coronary artery calcium scoring using ECG-gated multidetector CT: effect of individually optimized image-reconstruction windows on image quality and measurement reproducibility



Ajr. American Journal of Roentgenology 181(4): 1093-1100



We studied the effect of using individually optimized image-reconstruction windows on image quality and measurement reproducibility in coronary artery calcium scoring using ECG-gated multidetector CT (MDCT). In 50 patients, the coronary arteries were investigated twice with ECG-gated MDCT with 500-msec rotation time. Per scan, three sets of images were reconstructed, respectively, at an image-reconstruction window of 40%, 50%, and 60% of the R-R interval. Image quality was assessed, and the optimal image-reconstruction window per scan and per coronary territory was determined. The interscan variability of calcium mass measurements was calculated for different strategies (use of fixed image-reconstruction window [40%, 50%, or 60%] versus individually optimized image-reconstruction window). A significant improvement in image quality was obtained by selecting the best of three reconstructed data sets (mean image quality score, 4.4 vs 3.7; p < 0.001). Even with individually optimized image-reconstruction window values, we obtained high values for interscan variability (mean +/- SD, 27% +/- 22% vs 31% +/- 35% with a fixed image-reconstruction window). The use of individually optimized image-reconstruction windows leads to a significant improvement in image quality. However, interscan variability of calcium mass measurements remains high.

(PDF emailed within 0-6 h: $19.90)

Accession: 048666150

Download citation: RISBibTeXText

PMID: 14500239

DOI: 10.2214/ajr.181.4.1811093


Related references

Achieving consistent image quality with dose optimization in 64-row multidetector computed tomography prospective ECG gated coronary calcium scoring. International Journal of Cardiovascular Imaging 27(4): 611-617, 2011

Effect of the reconstruction window obtained at the isovolumic relaxation period on the image quality in electrocardiographic-gated 16-multidetector-row computed tomography coronary angiography studies. Journal of Computer Assisted Tomography 30(2): 258-261, 2006

Iterative beam-hardening correction with advanced modeled iterative reconstruction in low voltage CT coronary calcium scoring with tin filtration: Impact on coronary artery calcium quantification and image quality. Journal of Cardiovascular Computed Tomography 11(5): 354-359, 2017

Comparison of image quality of 64-slice multidetector CT coronary CT angiography using automated and manual multiphase methods for the determination of optimal phases for image reconstruction in patients with various mean heart rates. International Journal of Cardiovascular Imaging 26 Suppl 1: 41-52, 2010

Hybrid ECG-gated versus non-gated 512-slice CT angiography of the aorta and coronary artery: image quality and effect of a motion correction algorithm. Acta Radiologica 59(2): 170-179, 2017

Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality. La Radiologia Medica 122(12): 893-901, 2017

CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction. European Radiology 23(1): 125-132, 2013

Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. European Radiology 12(11): 2670-2678, 2002

Effect of slice thickness on image quality and the accuracy of gated computed tomography scanning for coronary calcium. Journal of the American College of Cardiology 43(5 Supplement A): 336A, March 3, 2004

Comparative assessment of three image reconstruction techniques for image quality and radiation dose in patients undergoing abdominopelvic multidetector CT examinations. British Journal of Radiology 86(1021): 20120161, 2013

Challenges in quantitative electron-beam computed tomography measurement of coronary artery calcium:; Image artifacts, scan protocols, and coronary artery calcium scores(1). Academic Radiology 11(6): 698-710, 2004

Measurement of coronary artery calcium with dual-slice helical CT compared with coronary angiography: evaluation of CT scoring methods, interobserver variations, and reproducibility. Ajr. American Journal of Roentgenology 167(2): 439-444, 1996

Influence of cardiac rhythm on image quality of 64-slice multidetector-row CT coronary angiography and clinic value of post-processing technology with image. Sichuan Da Xue Xue Bao. Yi Xue Ban 39(2): 305-308, 2008

Variation of the coronary calcium score depending on image reconstruction interval and scoring algorithm. Investigative Radiology 37(9): 496-502, 2002

Electrocardiography-Gated Computed Tomography of the Bronchial Arteries With Iterative Image Reconstruction: Clinical Evaluation and Image Quality. Journal of Computer Assisted Tomography 41(6): 970-975, 2017