Determination of chromium(III) and total chromium in water by derivative atomic absorption spectrometry using flow injection on-line preconcentration with a double microcolumn



Determination of chromium(III) and total chromium in water by derivative atomic absorption spectrometry using flow injection on-line preconcentration with a double microcolumn



Analytical Sciences 19(4): 589-592



A rapid and sensitive method has been proposed for the sequential determination of chromium(III) and total chromium in water samples by flame atomic absorption spectrometry combined with a flow injection on-line preconcentration on a double-microcolumn. The chromium(III) and total chromium in samples were retained on a double-microcolumn with a cation exchange resin, respectively, and eluted directly into a nebulizer by 3 mol L(-1) HNO3. The characteristic concentration (gives a derivative absorbance of 0.0044) and the detection limit (3sigma) for chromium were 0.512 microg L(-1) and 0.647 microg L(-1) for a preconcentration time of 1 min, respectively. This is an improvement of 20 and 14-times than those of conventional FI-FAAS. The proposed method allows the determination of chromium in the range of 0-90 microg L(-1) with a relative standard deviation of 3.63% at the 10 microg L(-1) level. The method has been applied for the analysis of chromium in reference water of National Research Center for Certified Reference Materials (GBW08607) and other water samples with satisfactory results.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 048750616

Download citation: RISBibTeXText

PMID: 12725397

DOI: 10.2116/analsci.19.589


Related references

Differential determination of chromium(VI) and total chromium in natural waters using flow injection on-line separation and preconcentration electrothermal atomic absorption spectrometry. Analyst 117(3): 629-635, 1992

High-performance flow flame atomic absorption spectrometry for automated on-line separation and determination of chromium(III)/chromium(VI) and preconcentration of chromium(VI). Analytical Chemistry 65(19): 2590-2595, 1993

Determination of chromium(III) and chromium(VI) in water using flow injection on-line preconcentration with selective adsorption on activated alumina and flame atomic absorption spectrometric detection. Analytical Chemistry 64(24): 3101-3108, 1992

Preconcentration and speciation of chromium by the determination of total chromium and chromium(III) in natural waters by flame atomic absorption spectrometry with a chelating ion-exchange flow infection system. Analytica Chimica Acta 327(1): 37-45, 1996

Speciative determination of chromium and chromium using flow-injection on-line preconcentration and flame atomic-absorption spectrometric detection. Analytica Chimica Acta 369(1-2): 69-77, Aug 10, 1998

Speciative determination of chromium(VI) and chromium(III) using flow-injection on-line preconcentration and flame atomic-absorption spectrometric detection. Analytica Chimica Acta 369(1-2): 69-77, 1998

On-line preconcentration and determination of chromium in parenteral solutions by flow injection-flame atomic absorption spectrometry. Journal of Pharmaceutical and Biomedical Analysis 31(1): 117-124, 2003

On-line chromatographic separation and determination of chromium(III) and chromium(VI) with preconcentration of the chromium(III) using potassium hydrogen phthalate, in various samples by flame atomic absorption spectrometry. Journal of Analytical Atomic Spectrometry 11(11): 1067-1074, 1996

Determination of chromium in different oxidation states by selective on-line preconcentration on cellulose sorbents and flow-injection flame atomic absorption spectrometry. Analytica Chimica Acta 288(3): 247-257, 1994

Determination of chromium(III) and chromium(VI) in water using flow injection on-line preconcentration and separation with flame absorption spectrometric detection. Guang Pu Xue Yu Guang Pu Fen Xi 23(3): 572-575, 2003

On-line coupling of flow injection microcolumn separation and preconcentration to electrothermal atomic absorption spectrometry for determination of (Ultra)trace selenite and selenate in water. Analytical Chemistry Washington 71(19): 4353-4360, 1999

On-line coupling flow injection microcolumn separation and preconcentration to electrothermal atomic absorption spectrometry for determination of (ultra)trace selenite and selenate in water. Analytical Chemistry 71(19): 4353-4360, 2000

On-line filtration system for determining total chromium and chromium in the soluble fraction of industrial effluents by flow injection flame atomic absorption spectrometry. Analytical and Bioanalytical Chemistry 373(1-2): 98-102, 2002

Speciation of chromium (VI) and total chromium determination in welding dust samples by flow-injection analysis coupled to atomic absorption spectrometry. Talanta 43(11): 1965-1974, 1996

Chromium Speciation Using Flow-injection Preconcentration on Xylenol Orange Functionalized Amberlite XAD-16 and Determination in Industrial Water Samples by Flame Atomic Absorption Spectrometry. Analytical Sciences 31(12): 1303-1308, 2015