Dialyzer reprocessing: improved treatment quality and increased dialyzer reuse using a team approach



Dialyzer reprocessing: improved treatment quality and increased dialyzer reuse using a team approach



Nephrology Nursing Journal 27(5): 483-488



Use of the performance improvement process can yield unexpected positive results. Through the implementation of performance improvement concepts, the Dialysis Centers of Dayton LLC East was able to increase the average dialyzer reuse number and achieve economical benefits while improving the quality of patient care delivered. Employment of the team approach, staff education, and communication was vital to the success of this Over the last 10 years, the use of dialyzer reprocessing has steadily increased in dialysis units across the country. If the reuse average was down in a unit, it was not uncommon to look to the reuse staff for an explanation, since it is "their" job to keep the numbers up. After consultation with a Minntech representative, the Dialysis Centers of Dayton LLC East staff discovered that the most effective methods to increase the average reuse number were those implemented on the dialyzer before it ever reached the reprocessing area. Several technical changes were initiated, including the use of standardized heparin protocols, all of which contributed to the improvement in the reuse average. Although some of these changes had been done previously, they were not implemented and reviewed according to the formal performance improvement model. Two methods for calculating the reuse average were employed. Over a 12-month time frame, reuse numbers increased from 7.1 and 7.5 to 36.6 and 18.1, respectively (utilizing the Hartline [1996] and conventional method of reuse calculation). Review of patient adequacy showed no detrimental effects and a slight improvement in the percentage of patients with a Kt/V of more than 1.2. Focusing on performance improvement in the reprocessing area has yielded many benefits to both patients and staff.

(PDF emailed within 1 workday: $29.90)

Accession: 048781243

Download citation: RISBibTeXText

PMID: 16649323



Related references

Dialyzer reuse: Interaction between dialyzer membrane, disinfectant (formalin), and blood during dialyzer reprocessing. Artificial Organs 20(1): 53-55, 1996

Dialyzer reuse following manual reprocessing with a new sterilant, RenNew-D. Artificial Organs 11(2): 132-136, 1987

Dialyzer reuse impact on dialyzer efficiency, patient morbidity and mortality and cost effectiveness. Saudi Journal of Kidney Diseases and Transplantation 12(3): 305-311, 2008

Effect of dialyzer membrane and dialyzer reuse on plasma lipid levels in end stage renal disease patients on hemodialysis. Journal of the American Society of Nephrology 7(9): 1494, 1996

Effect of dialyzer membrane and dialyzer reuse on serum lipid levels in end stage renal disease patients on hemodialysis. Journal of the American Society of Nephrology 6(3): 585, 1995

Effect of dialyzer membrane and dialyzer reuse on plasma lipid levels in end stage renal disease patients Results of a pilot study. Journal of the American Society of Nephrology 9(PROGRAM AND ABSTR ISSUE): 249A, Sept, 1997

Comparison of the EX03 dialyzer cartridge and the high performance ultra-flo II (UFII) coil dialyzer with the Gambro-Lundia plate dialyzer (GL). Proceedings of the Clinical Dialysis and Transplant Forum 2: 48-51, 1972

An improved method for dialyzer reprocessing using heat. Journal of the American Society of Nephrology 4(3): 363, 1993

Increased dialyzer reuse with citrate dialysate. Hemodialysis International. International Symposium on Home Hemodialysis 9(3): 264-267, 2005

Comparison of Quality of Life between Patients Undergoing Chronic Hemodialysis with Reusable Dialyzer and Single-Use Dialyzer: A Retrospective Cohort Study. Acta Medica Indonesiana 50(3): 222-229, 2018

Abandoning peracetic acid-based dialyzer reuse is associated with improved survival. Clinical Journal of the American Society of Nephrology 6(2): 297-302, 2011

Dialyzer reuse regeneration and quality tests. Artificial Organs 5A: 15, 1981

Improved dialyzer reuse after use of a population pharmacodynamic model to determine heparin doses. American Journal of Kidney Diseases 35(1): 89-94, 2000

A quality and cost-benefit analysis of dialyzer reuse in hemodialysis patients. Renal Failure 30(5): 521-526, 2008

Influence of erythropoietin treatment on dialyzer reuse. Blood Purification 15(2): 77-83, 1997