Effect of different inspiratory rise time and cycling off criteria during pressure support ventilation in patients recovering from acute lung injury



Effect of different inspiratory rise time and cycling off criteria during pressure support ventilation in patients recovering from acute lung injury



Critical Care Medicine 31(11): 2604-2610



With many mechanical ventilators, it is possible to modify the time to reach the selected airway pressure and the criteria for cycling off the inflation during pressure support ventilation. This study evaluated the effect of different inspiratory rise time and cycling off criteria on breathing pattern and work of breathing. Clinical study. University laboratory. Ten intubated patients recovering from acute lung injury (PaO2/FiO2 245 +/- 26 torr, positive end-expiratory pressure 9 +/- 3 cm H2O). We studied two inspiratory rise time criteria (shortest and longest, 0% and 40% of the breath cycle time) and two cycling off criteria (lowest and highest, 5% and 40% of the peak inspiratory flow) at 5 and 15 cm H2O of pressure support. Respiratory rate, tidal volume, and inspiratory and expiratory work of breathing (WOBI and WOBE) were measured. At both levels of pressure support ventilation, the shortest inspiratory rise time significantly reduced the WOBI from 0.77 +/- 0.32 to 0.56 +/- 0.23 J/L and from 0.24 +/- 0.28 to 0.08 +/- 0.09 J/L without affecting respiratory rate or tidal volume. At 15 cm H2O of pressure support ventilation, the lowest cycling off criteria significantly reduced respiratory rate from 24.9 +/- 12.1 to 21.5 +/- 12.7 beats/min and increased tidal volume from 0.51 +/- 0.17 to 0.60 +/- 0.26 L. At both levels of pressure support ventilation, the modification of cycling off criteria did not influence WOBI and WOBE. Our results suggest that in patients recovering from acute lung injury during pressure support ventilation, a) the shortest inspiratory rise time reduces the WOBI; and b) at 15 cm H2O of pressure support ventilation, the lowest cycling off criteria reduces the respiratory rate and increases the tidal volume without modifying the WOBI and WOBE. Modifications of inspiratory rise time and cycling off criteria must be carefully adjusted during pressure support ventilation.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 048874126

Download citation: RISBibTeXText

PMID: 14605531

DOI: 10.1097/01.CCM.0000089939.11032.36


Related references

Relationship between work of breathing provided by a ventilator and patients' inspiratory drive during pressure support ventilation; effects of inspiratory rise time. Anaesthesia and Intensive Care 29(4): 349-358, 2001

Effects of inspiratory rise time on triggering work load during pressure-support ventilation: a lung model study. Respiratory Care 55(7): 878-884, 2010

Effects of Inspiratory Pressure Rise Time and Hypoxic or Hypercapnic Breathing on Inspiratory Laryngeal Constrictor Muscle Activity During Nasal Pressure Support Ventilation. Critical Care Medicine 43(8): E296-E303, 2015

End-inspiratory airway occlusion: a method to assess the pressure developed by inspiratory muscles in patients with acute lung injury undergoing pressure support. American Journal of Respiratory and Critical Care Medicine 156(4 Pt 1): 1210-1216, 1997

Effect on inspiratory cycling-off synchronization with different expiratory trigger sensitivity level during pressure-support ventilation: a lung model study. Zhonghua Yi Xue Za Zhi 94(38): 2977-2981, 2015

Effect of breath termination criteria and endotracheal tube leak on tidal volume and inspiratory time in pressure support ventilation. Pediatric Research 41(4 PART 2): 257A, 1997

Effect of different cycling-off criteria and positive end-expiratory pressure during pressure support ventilation in patients with chronic obstructive pulmonary disease. Critical Care Medicine 35(11): 2547-2552, 2007

Pressure support ventilation in patients with acute lung injury. Critical Care Medicine 28(5): 1269-1275, 2000

Comparing the effects of rise time and inspiratory cycling criteria on 6 different mechanical ventilators. Respiratory Care 58(3): 465-473, 2014

Comparing the Effects of Rise Time and Inspiratory Cycling Criteria on 6 Different Mechanical Ventilators. 2013

Simulation of late inspiratory rise in airway pressure during pressure support ventilation. Respiratory Care 60(2): 201-209, 2016

Pressure support ventilation and intermittent positive pressure ventilation in acute lung injury. Chest 94(1 SUPPL): 2S, 1988

Arterial oxygenation and respiratory drive during pressure support ventilation in acute lung injury patients. American Review of Respiratory Disease 143(4 PART 2): A690, 1991

Comparison of pressure- and flow-triggered pressure-support ventilation on weaning parameters in patients recovering from acute respiratory failure. Critical Care Medicine 25(5): 756-760, 1997

The effects of pressure- and flow-triggered pressure support ventilation on weaning parameters in patients recovering from acute respiratory failure. Intensive Care Medicine 22(1 Supplement): S118-0, 1996