EurekaMag.com logo
+ Site Statistics
References:
53,623,987
Abstracts:
29,492,080
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Elemental speciation by parallel elemental and molecular mass spectrometry and peak profile matching



Elemental speciation by parallel elemental and molecular mass spectrometry and peak profile matching



Analytical Chemistry 78(24): 8445-8455



Trace elemental speciation in complex, real-world matrixes is a daunting task because of the low concentration of metals/metalloids and the correspondingly high molecular chemical noise. We constructed a liquid chromatography parallel elemental and molecular mass spectrometry (PEMMS) system and evaluated the use of peak elution profiles to identify trace molecular species containing specific heteroatoms, using the case of Se in yeast. We demonstrate that it is possible to use the HPLC-inductively coupled plasma (ICP)MS peak profile (retention time, width) to identify candidate ions with matching peak profiles in the molecular MS data. Proof of principle was demonstrated by C18 separation of three Se-amino acid standards (0.005-15 ppm as Se). The molecular MS (atmospheric pressure chemical ionization time-of-flight, APCI-TOF-MS) data set was converted into selected ion chromatograms of 0.05 Th width. ICPMS and APCI-TOF-MS ion chromatograms were fit by the Haarhoff-VanderLinde function using the following parameters: area, retention time, width, and skew. The ICPMS fit parameters were more reproducible than the APCI-TOF-MS fit parameters from run to run, and the APCI-TOF-MS signal was expected to limit correlation in most circumstances. Retention time and width were found to correlate well between the two MS systems for APCI-TOF-MS peaks with signal-to-fit-error (S/FE) of >25. Correction factors for differences in flow path length and peak broadening were required. The normalized correction factors were species and concentration independent and were stable from run to run. The skew parameter was found to be highly susceptible to noise and was not generally useful in matching ICPMS and APCI-TOF-MS peaks. An artificially noisy sample was generated by spiking 30 ppb Se-methionine (SeMet) and 5 ppb Se-methylselenocysteine (SeMSC) with unselenized yeast extract and run by PEMMS. The PEMMS software was able to detect four molecular MS peaks associated with SeMet and two for SeMSC, while filtering out >40 coeluting spectral peaks associated with chemical noise in each sample. In summary, we have demonstrated that correlated information in peak shape between parallel detectors can facilitate detection of trace elemental species in complex matrixes.

(PDF same-day service: $19.90)

Accession: 048937839

Download citation: RISBibTeXText

PMID: 17165838

DOI: 10.1021/ac0612170



Related references

Parallel elemental and molecular mass spectrometry (PEMMS) for speciation of metals in complex matrices. Eos, Transactions, American Geophysical Union 87(Fall Meeting Supplement): (Abstract V21A-0552, 2006

Elemental and molecular mass spectrometry for speciation analysis. Analytical and Bioanalytical Chemistry 390(7): 1683-1684, 2008

Bridging the gap between molecular and elemental mass spectrometry: higher energy collisional dissociation (HCD) revealing elemental information. Analytical Chemistry 87(3): 1613-1621, 2014

Laser ablation based bioimaging with simultaneous elemental and molecular mass spectrometry: towards spatially resolved speciation analysis. Rapid Communications in Mass Spectrometry 27(23): 2588-2594, 2014

The potential and challenges of elemental speciation by capillary electrophoresis-inductively coupled plasma mass spectrometry and electrospray or ion spray mass spectrometry. Spectrochimica Acta Part B Atomic Spectroscopy 53(2): 239-251, 1998

Speciation studies of vanadium in human liver (HepG2) cells after in vitro exposure to bis(maltolato)oxovanadium(IV) using HPLC online with elemental and molecular mass spectrometry. Metallomics 5(12): 1685-1697, 2014

Elemental speciation with plasma mass spectrometry. Analytical Chemistry 65(13): 585a-597a, 1993

Speciation studies of cis-platin adducts with DNA nucleotides via elemental specific detection (P and Pt) using liquid chromatography-inductively coupled plasma-mass spectrometry and structural characterization by electrospray mass spectrometry. Journal of Analytical Atomic Spectrometry 21(9): 861-868, 2006

New approaches for elemental speciation using plasma mass spectrometry. American Laboratory (Shelton) 32(3): 17-39, 2000

Electrospray mass spectrometry: A tool for elemental speciation. Spectrochimica Acta Part B Atomic Spectroscopy 54(12): 1649-1695, Nov 22, 1999

Use of ionspray mass spectrometry in the speciation and elemental characterization of metallothioneins. Journal of Analytical Atomic Spectrometry 12(5): 525-530, 1997

Elemental speciation analysis in biochemistry by electrospray mass spectrometry. Trends in Analytical Chemistry 19(5): 300-313, 2000

Elemental mass spectrometry: a powerful tool for an accurate characterisation at elemental level of quantum dots. Chemical Communications: 3107-3109, 2009

Paradigms in isotope dilution mass spectrometry for elemental speciation analysis. Analytica Chimica Acta 607(2): 115-125, 2008

Recent directions of electrospray mass spectrometry for elemental speciation analysis. Analytical and Bioanalytical Chemistry 400(6): 1645-1652, 2011