+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Evaluation of NO(x) flue gas analyzers for accuracy and their applicability for low-concentration measurements



Evaluation of NO(x) flue gas analyzers for accuracy and their applicability for low-concentration measurements



Journal of the Air and Waste Management Association 53(6): 749-758



The requirements of the Texas State Implementation Plan of the U.S. Clean Air Act for the Houston-Galveston Ozone Nonattainment Area stipulate large reductions in oxides of nitrogen (NO(x)) emissions. A large number of sources at Dow Chemical Co. sites within the nonattainment area may require the addition of continuous emission monitoring systems (CEMS) for online analysis of NO(x), CO, and O2. At the outset of this work, it was not known whether the analyzers could accurately measure NO(x) as low as 2 ppm. Therefore, NO(x) CEMS analyzers from five different companies were evaluated for their ability to reliably measure NO(x) in the 2-20 ppm range. Testing was performed with a laboratory apparatus that accurately simulated different mixtures of flue gas and, on a limited basis, simulated a dual-train sampling system on a gas turbine. The results indicate that this method is a reasonable approach for analyzer testing and reveal important technical performance aspects for accurate NO(x) measurements. Several commercial analyzers, if installed in a CEMS application with sampling conditioning components similar to those used in this study, can meet the U.S. Environmental Protection Agency's measurement data quality requirements for accuracy.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 048993002

Download citation: RISBibTeXText

PMID: 12828335


Related references

Evaluation of No x Flue Gas Analyzers for Accuracy and Their Applicability for Low-Concentration Measurements. Journal of the Air & Waste Management Association 53(6): 749-758, 2003

Comparative evaluation of routine applicability of three analyzers for mechanized urine dipstick measurement. Journal of Clinical Chemistry & Clinical Biochemistry 26(11): 759-760, 1988

Evaluation of the accuracy and reliability of measurements of the concentration of dust by the weight method of determination. Gigiena i Sanitariia 38(2): 61-65, 1973

Breath alcohol analyzers with electrochemical sensory--accuracy of measurements in lung model ventilation. Biomedizinische Technik. Biomedical Engineering 41(3): 54-59, 1996

Infrared analyzers for breast milk analysis: fat levels can influence the accuracy of protein measurements. Clinical Chemistry and Laboratory Medicine 55(12): 1931-1935, 2017

Evaluation of portable breath alcohol analyzers for accuracy. FASEB Journal 18(4-5): Abst 405 14, 2004

Accuracy evaluation of point-of-care glucose analyzers in the Saudi market. Saudi Medical Journal 33(1): 91-92, 2012

An evaluation of lipid measurements by four compact analyzers. Clinical Chemistry 40(6): 1059, 1994

Accuracy evaluation of commercial calcium analyzers using Japanese serum reference material. Clinical Chemistry 39(6): 1178, 1993

Accuracy of Raman lidar water vapor calibration and its applicability to long-term measurements. Applied Optics 47(30): 5592-5603, 2008

An evaluation of total cholesterol measurements by desk top analyzers. Clinical Chemistry 38(6): 1037, 1992

Evaluation of the accuracy in obtaining temporary characteristics of bioelectric processes for specialized multiparameter analyzers. Novosti Meditsinskoi Tekhniki 1975(1): 108-114, 1975

Precision and accuracy of Doppler flow measurements. In vitro and in vivo study of the applicability of the method in human fetuses. Scandinavian Journal of Clinical and Laboratory Investigation 47(4): 311-318, 1987

Evaluation of interference of glucose and lactate measurements in the AVL Omni-9 and comparison with four other analyzers. Clinical Chemistry 44(6 Part 2): A138, 1998

Accuracy evaluation and hematocrit effect of commercial ionized calcium analyzers using Japanese serum reference material. Scandinavian Journal of Clinical and Laboratory Investigation. Supplementum 224: 173-177, 1996