Evaluation of TEM samples of an Mg-Al alloy prepared using FIB milling at the operating voltages of 10 kV and 40 kV



Evaluation of TEM samples of an Mg-Al alloy prepared using FIB milling at the operating voltages of 10 kV and 40 kV



Journal of Electron Microscopy 53(5): 459-463



Transmission electron microscopy (TEM) samples of an Mg-Al alloy has been prepared using a Ga-focused ion beam (FIB) milling at two different operating voltages of 10 kV and 40 kV to investigate the influence of the FIB energy on the sample quality. The fine structures of the samples have been studied using a high resolution TEM, and the concentration of the implanted Ga was analysed using an energy dispersive X-ray (EDX) analysis. The result of the TEM observation revealed that point defects were introduced to the sample finally milled at 40 kV but not at 10 kV. However, crystal lattice images and electron diffraction patterns were clearly observed on both the samples. The typical influence of the FIB energy was indicated in the elemental analysis. The relative Ga concentration in the thin sample finally milled at 10 kV was 1.0-2.0 at% that is less than half of 4.0-6.0 at% of the Ga concentration in the sample finally milled at 40 kV. A comparison between the experimental results of the Ga concentration measurement with simulation was also discussed.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 048993125

Download citation: RISBibTeXText

PMID: 15582947

DOI: 10.1093/jmicro/dfh058


Related references

The nanostructure and hydrogenation reaction of Mg50Co50 BCC alloy prepared by ball-milling. Nanotechnology 20(20): 204015, 2009

Dependence of milling time on electrochemical properties of nano Si electrodes prepared by ball-milling. Journal of Nanoscience and Nanotechnology 11(7): 6262-6265, 2011

Design and evaluation of injectable niclosamide nanocrystals prepared by wet media milling technique. Drug Development and Industrial Pharmacy 41(9): 1416-1424, 2015

Rugosimetric evaluation on the proximal aspect of specimens prepared with four brands of silver alloy. Revista Da Faculdade de Odontologia Da Universidade de Sao Paulo 10(2): 169-172, 1972

In vitro/in vivo evaluation of felodipine micropowders prepared by the wet-milling process combined with different solidification methods. Drug Development and Industrial Pharmacy 40(7): 929-936, 2014

Clinical evaluation of corrosion resistance of conventional alloy, spherical-particle alloy, and dispersion-phase alloy. Journal of Prosthetic Dentistry 25(6): 650-656, 1971

Evaluation of laboratory mills for milling small samples of rice. Applied Engineering in Agriculture 18(5): 577-583, 2002

Corn dry-milling: A comparative evaluation of commercial degerminator samples. Cereal Chem 41(5): 321-328, 1964

Guide for uprating REA transmission structures for higher operating voltages. 1981

Development and evaluation of optimized sucrose ester stabilized oleanolic acid nanosuspensions prepared by wet ball milling with design of experiments. Biological and Pharmaceutical Bulletin 37(6): 926-937, 2014

Evaluation of the IRRI Test Tube mill for use in milling small samples of rice. Research Series Arkansas Agricultural Experiment Station (485): 231-237, 2001

In situ trapping of mercury vapors on Au, Pd-Au alloy or Pt-Rh alloy in the graphite furnace for the determination of Hg in environmental samples after microwave digestion. Atomic Spectroscopy 18(5): 166-168, 1997

A charge transfer single crystal field effect transistor operating at low voltages. Chemical Communications 49(52): 5847-5849, 2013

Photorefractive polymer device with video-rate response time operating at low voltages. Optics Letters 31(10): 1408-1410, 2006

Combining FIB milling and conventional Argon ion milling techniques to prepare high-quality site-specific TEM samples for quantitative EELS analysis of oxygen in molten iron. Journal of Microscopy 238(3): 200-209, 2010