+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Evaluation of a 3D digital photographic imaging system of the human face



Evaluation of a 3D digital photographic imaging system of the human face



Journal of Oral Rehabilitation 34(3): 201-205



The aim of this study was to investigate the accuracy of a 3D photographic imaging system for potential application in fabrication of maxillofacial prostheses. For validity estimates, computer digitized 3D photographic images of calibrated ruler attached to a model were analysed for linear and curvilinear distances in 1 mm increments (1-50 mm from the centre of the image). Distortion was evaluated from 1 mm distances measured 20, 40 and 60 mm from the centre of the field. To estimate reliability of measurements in vivo, two raters measured the right endocanthion-subnasale distance and the distance between right and left endocathion on images of 10 subjects, repeated three times (30 images total). From the digital file for one subject, a rapid prototyping (RP) machine produced a 3D model of the mid-face. Measures from the model were compared with those of the 3D computer image to estimate error in fabrication. Mean error values for calibrated distances ranged from 0.07 to 0.26 mm for linear distances, 0.08-0.34 mm for curvilinear distances, and 0.06-0.12 mm for distortion from the centre. Intra- and interexaminer correlation ranged from 0.92 to 1.00 and 0.94-1.00 respectively. Measures of the endocanthion and subnasale distances on the RP fabricated mid-face model were within 8% of the corresponding measures on 3D computer images. The accuracy of the photographic 3D imaging system tested was sufficient for clinical description of the mid-face structures and may be potentially useful for rapid prototyping of facial prostheses.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 048993193

Download citation: RISBibTeXText

PMID: 17302948

DOI: 10.1111/j.1365-2842.2006.01663.x


Related references

Digital photographic imaging system for the evaluation of various facial skin lesions. Conference Proceedings 2008: 4032-4034, 2008

Evaluation of an indirect ophthalmoscopy digital photographic system as a retinopathy of prematurity screening tool. Journal of Aapos 18(1): 36-41, 2014

Development of a digital imaging system for objective measurement of hyperpigmented spots on the face. Skin Research and Technology 8(4): 227-235, 2002

Evaluation of an automated digital imaging system, Nextslide Digital Review Network, for examination of peripheral blood smears. Archives of Pathology and Laboratory Medicine 136(6): 660-667, 2012

Utilization of a high-resolution digital imaging system for the objective and quantitative assessment of hyperpigmented spots on the face. Skin Research and Technology 8(2): 73-77, 2002

Digital imaging for photographic collections. 1999

Photographic images, digital imaging, dermatology, and the law. Archives of Dermatology 140(4): 473-476, 2004

Digital fundus imaging: a comparison with photographic techniques. Annals of Ophthalmology 23(2): 46-53, 1991

Digital imaging and teledermatology: Educational and diagnostic applications of a portable digital imaging system for the trainee dermatologist. Clinical and Experimental Dermatology 22(4): 163-165, 1997

Investigation of basic imaging properties in digital radiography. 11. Multiple slit-beam imaging technique with image intensifier-TV digital system. Medical Physics 14(5): 736-743, 1987

A novel method for the photographic recovery of fingermark impressions from ammunition cases using digital imaging. Journal of Forensic Sciences 60(2): 418-421, 2015

Imaging characteristics evaluation of a digital radiography system. LaRadiologiaMedica106(1-2):94, 2003

Clinical evaluation of a new digital chest imaging system. European Radiology 5(1): 83-87, 1995

An evaluation of the Sens-A-Ray digital dental imaging system. Dento Maxillo Facial Radiology 22(3): 121-126, 1993

The fully digital evaluation of photographic PIV recordings. Flow, Turbulence and Combustion 56(2-3): 79-102, 1996