Evaluation of a commercial electron treatment planning system based on Monte Carlo techniques (eMC)



Evaluation of a commercial electron treatment planning system based on Monte Carlo techniques (eMC)



Zeitschrift für Medizinische Physik 16(4): 313-329



A commercial electron beam treatment planning system on the basis of a Monte Carlo algorithm (Varian Eclipse, eMC V7.2.35) was evaluated. Measured dose distributions were used for comparison with dose distributions predicted by eMC calculations. Tests were carried out for various applicators and field sizes, irregular shaped cut outs and an inhomogeneity phantom for energies between 6 Me V and 22 MeV Monitor units were calculated for all applicator/energy combinations and field sizes down to 3 cm diameter and source-to-surface distances of 100 cm and 110 cm. A mass-density-to-Hounsfield-Units calibration was performed to compare dose distributions calculated with a default and an individual calibration. The relationship between calculation parameters of the eMC and the resulting dose distribution was studied in detail. Finally, the algorithm was also applied to a clinical case (boost treatment of the breast) to reveal possible problems in the implementation. For standard geometries there was a good agreement between measurements and calculations, except for profiles for low energies (6 MeV) and high energies (18 Me V 22 MeV), in which cases the algorithm overestimated the dose off-axis in the high-dose region. For energies of 12 MeV and higher there were oscillations in the plateau region of the corresponding depth dose curves calculated with a grid size of 1 mm. With irregular cut outs, an overestimation of the dose was observed for small slits and low energies (4% for 6 MeV), as well as for asymmetric cases and extended source-to-surface distances (12% for SSD = 120 cm). While all monitor unit calculations for SSD = 100 cm were within 3% compared to measure-ments, there were large deviations for small cut outs and source-to-surface distances larger than 100 cm (7%for a 3 cm diameter cut-out and a source-to-surface distance of 10 cm).

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 048993311

Download citation: RISBibTeXText

PMID: 17216757


Related references

Evaluation of a commercial electron treatment planning system based on Monte Carlo techniques (eMc). Zeitschrift für Medizinische Physik 16(4): 313-329, 2006

Evaluation of a commercial VMC++ Monte Carlo based treatment planning system for electron beams using EGSnrc/BEAMnrc simulations and measurements. Physica Medica 25(3): 111-121, 2009

Clinical use of a commercial Monte Carlo treatment planning system for electron beams. Physics in Medicine and Biology 50(5): 1029-1034, 2005

Evaluation of a commercial Monte Carlo dose calculation algorithm for electron treatment planning. Journal of Applied Clinical Medical Physics 20(6): 184-193, 2019

Dosimetric verification of a commercial Monte Carlo treatment planning system (VMC++) for a 9 MeV electron beam. Medical Physics 36(5): 1759-1767, 2009

Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning. Medical Physics 31(1): 142-153, 2004

Optimal electron-beam treatment planning for retinoblastoma using a new three-dimensional Monte Carlo-based treatment planning system. Medical Physics 19(1): 125-135, 1992

Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MV. Medical Physics 31(10): 2771-2779, 2004

First macro Monte Carlo based commercial dose calculation module for electron beam treatment planning--new issues for clinical consideration. Physics in Medicine and Biology 51(11): 2781-2799, 2006

Interface software for DOSXYZnrc Monte Carlo dose evaluation on a commercial radiation treatment planning system. Radiation Medicine 25(6): 309-314, 2007

Experimental validation of a Monte Carlo-based treatment-planning system for electron beams. Strahlentherapie und Onkologie 183(3): 150-156, 2007

Evaluation of the accuracy of various dose calculation algorithms of a commercial treatment planning system in the presence of hip prosthesis and comparison with Monte Carlo. Journal of Cancer Research and Therapeutics 13(3): 501-509, 2018

Dosimetric validation of a commercial Monte Carlo based IMRT planning system. Medical Physics 37(2): 540-549, 2010

Experimental evaluation of a GPU-based Monte Carlo dose calculation algorithm in the Monaco treatment planning system. Journal of Applied Clinical Medical Physics 17(6): 230-241, 2016

The omega project treatment planning for electron beam radiotherapy using monte carlo techniques. Physics in Medicine & Biology 35(2): 285-286, 1990