+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Evaluation of a fiberoptic-based system for measurement of optical properties in highly attenuating turbid media



Evaluation of a fiberoptic-based system for measurement of optical properties in highly attenuating turbid media



Biomedical Engineering Online 5: 49



Accurate measurements of the optical properties of biological tissue in the ultraviolet A and short visible wavelengths are needed to achieve a quantitative understanding of novel optical diagnostic devices. Currently, there is minimal information on optical property measurement approaches that are appropriate for in vivo measurements in highly absorbing and scattering tissues. We describe a novel fiberoptic-based reflectance system for measurement of optical properties in highly attenuating turbid media and provide an extensive in vitro evaluation of its accuracy. The influence of collecting reflectance at the illumination fiber on estimation accuracy is also investigated. A neural network algorithm and reflectance distributions from Monte Carlo simulations were used to generate predictive models based on the two geometries. Absolute measurements of diffuse reflectance were enabled through calibration of the reflectance system. Spatially-resolved reflectance distributions were measured in tissue phantoms at 405 nm for absorption coefficients (mu(a)) from 1 to 25 cm-1 and reduced scattering coefficients (mu'(s)) from 5 to 25 cm-1. These data and predictive models were used to estimate the optical properties of tissue-simulating phantoms. By comparing predicted and known optical properties, the average errors for mu(a) and mu'(s) were found to be 3.0% and 4.6%, respectively, for a linear probe approach. When bifurcated probe data was included and samples with mu(a) values less than 5 cm-1 were excluded, predictive errors for mu(a) and mu'(s) were further reduced to 1.8% and 3.5%. Improvements in system design have led to significant reductions in optical property estimation error. While the incorporation of a bifurcated illumination fiber shows promise for improving the accuracy of mu's estimates, further study of this approach is needed to elucidate the source of discrepancies between measurements and simulation results at low mu(a) values.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 048993416

Download citation: RISBibTeXText

PMID: 16928274

DOI: 10.1186/1475-925x-5-49


Related references

Effect of refractive index on the measurement of optical properties in turbid media. Applied Optics 40(10): 1735-1741, 2001

Measurement of internal tissue optical properties at ultraviolet and visible wavelengths: Development and implementation of a fiberoptic-based system. Optics Express 16(12): 8685-8703, 2008

Measurement of the local optical properties of turbid media by differential path-length spectroscopy. Applied Optics 43(15): 3048-3054, 2004

Implementation of the swept source optical coherence tomography (SSOCT) system with a statistical method to analyze optical properties of turbid media. Optik - International Journal for Light and Electron Optics 127(4): 1656-1659, 2016

Reflectance-based determination of optical properties in highly attenuating tissue. Journal of Biomedical Optics 8(2): 206-215, 2003

Lookup table-based inverse model for determining optical properties of turbid media. Journal of Biomedical Optics 13(5): 050501, 2008

Study of turbid media with light: recovery of mechanical and optical properties from boundary measurement of intensity autocorrelation of light. Journal of the Optical Society of America. A Optics Image Science and Vision 26(6): 1472-1483, 2009

Determination of the optical properties of turbid media by measurements of the spatially resolved reflectance considering the point-spread function of the camera system. Journal of Biomedical Optics 13(5): 054047, 2008

Robust metamodel-based inverse estimation of bulk optical properties of turbid media from spatially resolved diffuse reflectance measurements. Optics Express 23(21): 27880-27898, 2015

Measurement of the refractive index of highly turbid media. Optics Letters 35(8): 1224-1226, 2010

Picosecond magneto-optical phenomena in turbid media: toward magneto-optical characterization of highly scattering biological samples. Applied Optics 36(13): 2990-2994, 1997

Measurement of the magneto-optical correlation length in turbid media. Physical Review. E Statistical Nonlinear and Soft Matter Physics 66(5 Pt 2): 056610, 2002

Measurement of fluorophore concentration in turbid media by a single optical fiber. Medical Laser Application 22(1): 23-34, 2007

Do different turbid media with matched bulk optical properties also exhibit similar polarization properties?. Biomedical Optics Express 2(12): 3248-3258, 2011

Time-resolved optical diffusion tomographic image reconstruction in highly scattering turbid media. Proceedings of the National Academy of Sciences of the United States of America 93(24): 13561-13564, 1996