Evaluation of a flat panel digital radiographic system for low-dose portable imaging of neonates



Evaluation of a flat panel digital radiographic system for low-dose portable imaging of neonates



Medical Physics 30(4): 601-607



The purpose of this study was to evaluate the clinical utility of an investigational flat-panel digital radiography system for low-dose portable neonatal imaging. Thirty image-pairs from neonatal intensive care unit patients were acquired with a commercial Computed Radiography system (Agfa, ADC 70), and with the investigational system (Varian, Paxscan 2520) at one-quarter of the exposure. The images were evaluated for conspicuity and localization of the endings of ancillary catheters and tubes in two observer performance experiments with three pediatric radiologists and three neonatologists serving as observers. The results indicated no statistically significant difference in diagnostic quality between the images from the investigational system and from CR. Given the investigational system's superior resolution and noise characteristics, observer results suggest that the high detective quantum efficiency of flat-panel digital radiography systems can be utilized to decrease the radiation dose/exposure to neonatal patients, although post-processing of the images remains to be optimized. The rapid availability of flat-panel images in portable imaging was found to be an added advantage for timely clinical decision-making.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 048993421

Download citation: RISBibTeXText

PMID: 12722812

DOI: 10.1118/1.1556611


Related references

Effect on image data resampling in evaluation of the basic imaging properties for a digital radiographic system based on a flat panel detector. Nihon Hoshasen Gijutsu Gakkai Zasshi 63(7): 749-756, 2007

Physical imaging properties and low-contrast performance of a newly developed flat-panel digital radiographic system. Nihon Hoshasen Gijutsu Gakkai Zasshi 61(12): 1656-1665, 2005

Investigation of the accurate measurement of the basic imaging properties for the digital radiographic system based on flat panel detector. Nihon Hoshasen Gijutsu Gakkai Zasshi 64(7): 877-878, 2008

Portable flat-panel detector for low-dose imaging in a pediatric intensive care unit: comparison with an asymmetric film-screen system. Investigative Radiology 40(11): 736-741, 2005

Portable Flat-Panel Detector for Low-Dose Imaging in a Pediatric Intensive Care Unit. Investigative Radiology 40(11): 736-741, 2005

Estimated patient dose reduction in interventional cardiac procedures using a flat panel digital cardiac imaging system. Journal of the American College of Cardiology 37(2 Suppl. A): 5A, 2001

Dose performance evaluation of a charge coupled device and a flat-panel digital fluoroscopy system recently installed in an interventional cardiology laboratory. Radiation Protection Dosimetry 111(3): 297-304, 2004

Super-resolution variable-dose imaging in digital radiography: quality and dose reduction with a fluoroscopic flat-panel detector. International Journal of Computer Assisted Radiology and Surgery 6(5): 663-673, 2011

Radiation dose reduction with digital flat panel cardiac x-ray imaging. European Heart Journal 23(Abstract Suppl.): 71, August-September, 2002

Comparison of basic imaging properties for digital radiographic systems based on a direct conversion type of flat panel detector. Nihon Hoshasen Gijutsu Gakkai Zasshi 64(1): 41-49, 2008

Correlation between basic imaging properties and subjective evaluations of two digital radiographic X-ray systems based on direct-conversion flat panel detector. Nihon Hoshasen Gijutsu Gakkai Zasshi 66(11): 1457-1466, 2010

Performance evaluation of a direct-conversion flat-panel detector system in imaging and quality assurance for a high-dose-rate 192 Ir source. Physics in Medicine and Biology 63(5): 055017, 2018

Radiation dose reduction in scoliosis patients: low-dose full-spine radiography with digital flat panel detector and image stitching system. Rofo 183(7): 645-649, 2011

Reduction in operator X-ray exposure using a digital flat panel imaging system. Journal of the American College of Cardiology 37(2 Suppl. A): 5A, 2001

Is gridless angiography a dose-saving alternative on a Digital Flat Panel cardiac system?. European Heart Journal 23(Abstract Suppl.): 71, August-September, 2002