Evaluation of a generalized regression artificial neural network for extending cadmium's working calibration range in graphite furnace atomic absorption spectrometry



Evaluation of a generalized regression artificial neural network for extending cadmium's working calibration range in graphite furnace atomic absorption spectrometry



Analytical and Bioanalytical Chemistry 381(3): 788-794



A generalized regression artificial neural network (GRANN) was developed and evaluated for modeling cadmium's nonlinear calibration curve in order to extend its upper concentration limit from 4.0 microg L-1 up to 22.0 microg L-1. This type of neural network presents important advantages over the more popular backpropagation counterpart which are worth exploiting in analytical applications, namely, (1) a smaller number of variables have to be optimized, with the subsequent reduction in "development hassle"; and, (2) shorter development times, thanks to the fact that the adjustment of the weights (the artificial synapses) is a non-iterative, one-pass process. A backpropagation artificial neural network (BPANN), a second-order polynomial, and some less frequently employed polynomial and exponential functions (e.g., Gaussian, Lorentzian, and Boltzmann), were also evaluated for comparison purposes. The quality of the fit of the various models, assessed by calculating the root mean square of the percentage deviations, was as follows: GRANN>Boltzmann>second-order polynomial>BPANN>Gauss>Lorentz. The accuracy and precision of the models were further estimated through the determination of cadmium in the certified reference material "Trace Metals in Drinking Water" (High Purity Standards, Lot No. 490915), which has a cadmium certified concentration (12.00+/-0.06 microg L-1) that lies in the nonlinear regime of the calibration curve. Only the models generated by the GRANN and BPANN accurately predicted the concentrations of a series of solutions, prepared by serial dilution of the CRM, with cadmium concentrations below and above the maximum linear calibration limit (4.0 microg L-1). Extension of the working range by using the proposed methodology represents an attractive alternative from the analytical point of view, since it results in less specimen manipulation and consequently reduced contamination risks without compromising either the accuracy or the precision of the analyses. The implementation of artificial neural networks also helps to reduce the trial-and-error task of looking for the right mathematical model from among the many possibilities currently available in the various scientific and statistic software packages.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 048993440

Download citation: RISBibTeXText

PMID: 15688156

DOI: 10.1007/s00216-004-2918-1


Related references

Increasing the working calibration range by means of artificial neural networks for the determination of cadmium by graphite furnace atomic absorption spectrometry. Talanta 63(2): 425-431, 2004

Simultaneous Determination of Cadmium and Lead in Cigarettes and Cigarette Smoke by Impaction-Graphite Furnace and Graphite Furnace Atomic Absorption Spectrometry. Spectroscopy Letters 32(4): 615-621, 1999

Determination and safety evaluation of cadmium intakes in college students by graphite furnace atomic absorption spectrometry. Wei Sheng Yan Jiu 41(5): 739-742, 2013

Cadmium copper lead and zinc determination in precipitation a comparison of inductively coupled plasma atomic emission spectrometry and graphite furnace atomization atomic absorption spectrometry. Mikrochimica Acta 1(3-4): 159-170, 1986

The determination of cadmium by atomic absorption spectrometry with graphite furnace. Kancha Diqiu Wuli Kancha Diqiu Huaxue Wenji = Contribution to the Exploration [of] Geophysics and Geochemistry 1: 221-225, 1985

Determination of low levels of cadmium in marine and fresh water sediments by graphite furnace atomic absorption spectrometry employing a reduced palladium chloride modifier and by inductively coupled plasma atomic emission spectrometry. Journal of Analytical Atomic Spectrometry 6(1): 37-40, 1991

Determination of lead and cadmium in wines by graphite furnace atomic absorption spectrometry. Food Additives and Contaminants 21(2): 154-157, 2004

Determination of trace cadmium in 24-h diets by graphite furnace atomic absorption spectrometry. Journal of Agricultural & Food Chemistry 43(10): 2652-2657, 1995

Determination of cadmium in soil samples by graphite furnace atomic absorption spectrometry. Jilin Dizhi = Jilin Geology 24(2): 115-117, 2005

Determination of cadmium in rice by microwave digestion and graphite furnace atomic absorption spectrometry. Shokuhin Eiseigaku Zasshi = Journal of the Food Hygienic Society of Japan 41(1): 66-69, 2000

Determination of cadmium, cobalt, nickel in grain with Graphite Furnace Atomic Absorption Spectrometry. Guang Pu Xue Yu Guang Pu Fen Xi 17(1): 94-96, 1997

Determination of lead and cadmium in food and blood by inductively coupled plasma mass spectrometry: a comparison with graphite furnace atomic absorption spectrometry. Science of the Total Environment 205(2-3): 179-187, 1997

Direct calibration for determining aluminum in bone and soft tissues by graphite furnace atomic absorption spectrometry. Clinical Chemistry 37(3): 461-466, 1991

Role of a binary metallic modifier in the determination of cadmium in graphite furnace atomic absorption spectrometry. Analytical Sciences 26(7): 809-813, 2010

Simultaneous determination of lead, cadmium, nickel, and chromium using graphite furnace atomic absorption spectrometry. Nahrung 41(1): 54-54, 1997