Evaluation of a kinetic uricase method for serum uric acid assay by predicting background absorbance of uricase reaction solution with an integrated method



Evaluation of a kinetic uricase method for serum uric acid assay by predicting background absorbance of uricase reaction solution with an integrated method



Journal of Zhejiang University. Science. B 7(6): 497-502



A patented kinetic uricase method was evaluated for serum uric acid assay. Initial absorbance of the reaction mixture before uricase action (A(0)) was obtained by correcting the absorbance at 293 nm measured before the addition of uricase solution, and background absorbance (A(b)) was predicted by an integrated method. Uric acid concentration in reaction solution was calculated from A, the difference between A(0) and A(b), using the absorptivity preset for uric acid. This kinetic uricase method exhibited CV<4.3% and recovery of 100%. Lipids, bilirubin, hemoglobin, ascorbic acid, reduced glutathione and xanthine <0.32 mmol/L in serum had no significant effects. A linearly responded to 1.2 to 37.5 micromol/L uric acid in reaction solution containing 15 microl serum. The slope of linear response was consistent with the absorptivity preset for uric acid while the intercept was consistent with that for serum alone. Uric acid concentrations in clinic sera by different uricase methods positively correlated to each other. By Bland-Altman analysis, this kinetic uricase method accorded with that by quantifying the total change of UV absorbance on the completion of uricase reaction. These results demonstrated that this kinetic uricase method is reliable for serum uric acid assay with enhanced resistance to both xanthine and other common errors, wider range of linear response and much lower cost.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 048993470

Download citation: RISBibTeXText

PMID: 16691645

DOI: 10.1631/jzus.2006.b0497


Related references

Characterization of a uricase from Bacillus fastidious A.T.C.C. 26904 and its application to serum uric acid assay by a patented kinetic uricase method. Biotechnology and Applied Biochemistry 45(Pt 2): 75-80, 2006

A new method for the preparation of uricase and the effect of uricase on the blood uric acid levels of the chicken. Archives of Biochemistry 21(1): 158-165, 1949

Comparison of four methods for measuring uric acid: copper-chelate, phosphotungstate, manual uricase, and automated kinetic uricase. Clinical Chemistry 19(10): 1184-1186, 1973

Improvements of the uricase-u.v. method for the determination of uric acid in serum and urine. Clinica Chimica Acta; International Journal of Clinical Chemistry 14(5): 708-710, 1966

Hyperxanthinemia interferes with serum uric acid determinations by the uricase method. Clinical Chemistry 25(8): 1492-1494, 1979

Competitive inhibition of uricase by xanthine: an assay for xanthine oxldase activity in the presence of uricase by the in vitro production of uric acid. Fed Proc 11(1): 301-302, 1952

A new method for the determination of serum uric acid by measuring allantoid produced by the action of uricase. Chemical & Pharmaceutical Bulletin 28(11): 3375-3380, 1980

Negative interference with serum uric acid determinations by the uricase method due to hyper xanthinemia. Clinical Chemistry 25(6): 1082, 1979

A precise semi-automated uricase method for determining uric acid in serum or urine. Clinical Biochemistry 10(1): 29-31, 1977

A new method for the determination of serum uric acid by measuring allantoin produced by the action of uricase. Chemical & Pharmaceutical Bulletin 28(11): 3375-3380, 1980

Direct determination of uric acid in serum by a fluorometric-enzymatic method based on uricase. Talanta 54(5): 847-854, 21 June, 2001

Direct determination of uric acid in serum by a fluorometric-enzymatic method based on uricase. Talanta 54(5): 847-854, 2001

Evaluation of the technicon bound uricase ec 1.7.3.3 method for the determination of uric acid in urine. Journal of Clinical Chemistry and Clinical Biochemistry 20(5): 299-304, 1982

Evaluation of the Technicon bound uricase method for the determination of uric acid in urine. Journal of Clinical Chemistry and Clinical Biochemistry. Zeitschrift für Klinische Chemie und Klinische Biochemie 20(5): 299-303, 1982

Uric acid determinations reversed phase liquid chromatography with uv detection compared with kinetic and equilibrium adaptations of the uricase method. Clinical Chemistry 28(3): 496-498, 1982