Evaluation of a new continuous cardiac output monitor in off-pump coronary artery surgery



Evaluation of a new continuous cardiac output monitor in off-pump coronary artery surgery



Anaesthesia 59(4): 385-389



We evaluated a new, ultra-fast response continuous cardiac output monitor in 34 adult patients undergoing off-pump coronary artery bypass graft surgery. Cardiac output was measured with the TruCCOMS continuous cardiac output monitor (Aortech International plc, Lanarkshire, UK), using triplicate cold bolus thermodilution as the criterion standard, at fixed time points during surgery and during dobutamine infusion. The two techniques were compared using linear regression and Bland-Altman analysis. Overall, the study device displayed a bias of 0.4 l.min(-1) with limits of agreement of +2.5 l.min(-1) and -1.7 l.min(-1). The study device failed to detect the change in cardiac output caused by dobutamine accurately (y = 0.18x + 0.45; r(2) = 0.13), with an error linearly related to the magnitude of the change measured. We conclude that the device's failure to detect changes in cardiac output could be a major limitation in its clinical use in its current form.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 048993635

Download citation: RISBibTeXText

PMID: 15023110

DOI: 10.1111/j.1365-2044.2004.03668.x


Related references

Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery. Journal of Anesthesia 29(3): 416-420, 2015

Continuous cardiac output during off-pump coronary artery bypass surgery: pulse-contour analyses vs pulmonary artery thermodilution. British Journal of Anaesthesia 99(4): 484-492, 2007

Pro: continuous cardiac output and SvO₂monitoring should be routine during off-pump coronary artery bypass graft surgery. Journal of Cardiothoracic and Vascular Anesthesia 26(6): 1131-1135, 2012

Continuous cardiac output monitoring during haemodynamic changes in off-pump coronary artery bypass grafting surgery. European Journal of Anaesthesiology 23(10): 890-892, 2006

Continuous and bolus thermodilution cardiac output measurement during off-pump coronary artery bypass surgery.. Revista Brasileira de Anestesiologia 54(3): 319-324, 2004

The peri-operative use of the oesophageal Doppler monitor in patients undergoing coronary artery revascularisation. A comparison with the continuous cardiac output monitor. Anaesthesia 52(7): 624-629, 1997

Evaluation of continuous cardiac output in patients undergoing coronary artery bypass surgery. Anesthesiology 77(3A): A472, 1992

Comparison of uncalibrated arterial pressure waveform analysis with continuous thermodilution cardiac output measurements in patients undergoing elective off-pump coronary artery bypass surgery. Journal of Cardiothoracic and Vascular Anesthesia 24(5): 767-771, 2010

Con: continuous cardiac output and SvO₂monitoring are not routine in off-pump coronary artery bypass grafting. Journal of Cardiothoracic and Vascular Anesthesia 26(6): 1136-1138, 2012

A comparison of CardioQ and thermodilution cardiac output during off-pump coronary artery surgery. Journal of Cardiothoracic and Vascular Anesthesia 17(6): 728-732, 2003

Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery. Journal of Cardiothoracic and Vascular Anesthesia 20(3): 315-319, 2006

Outcome of intracoronary shunt in off-pump coronary artery bypass surgery in patients with low cardiac output. Acta Medica Iranica 52(10): 777-780, 2014

Cardiac output measurements during off-pump coronary surgery: comparison between partial rebreathing and pulmonary artery thermodilution. European Journal of Anaesthesiology 24(8): 720; Author Reply 721-720; Author Reply 721, 2007

Descending aortic pulsed wave Doppler can predict changes in cardiac output during off-pump coronary artery bypass surgery. Annals of Thoracic and Cardiovascular Surgery 9(5): 314-318, 2003