Evaluation of a new modified pediatric bubble oxygenator



Evaluation of a new modified pediatric bubble oxygenator



Cardiovascular Diseases 8(4): 569-574



A comparison was made of the S-070 Pediatric Bubble Oxygenator, which was unreliable above flow rates of approximately 1.5 L/min, with a modified S-070A, which proved to be extremely efficient to flow rates of 2.5 L/min.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 048993690

Download citation: RISBibTeXText

PMID: 15216187


Related references

Clinical experience with a membrane oxygenator, COBE VPCML, for pediatric open heart surgery--comparison with the bubble oxygenator. Kyobu Geka. Japanese Journal of Thoracic Surgery 40(2): 118-122, 1987

Comparative evaluation of a new disposable rotating membrane oxygenator with bubble oxygenator. Annals of Thoracic Surgery 21(1): 48-54, 1976

Clinical evaluation of the bentley 10 plus bubble oxygenator in comparison with the mera excelung membrane oxygenator. Japanese Journal of Artificial Organs 20(3): 1105-1109, 1991

A new membrane oxygenator: Capiox II. Comparative evaluation with a bubble oxygenator. Minerva Chirurgica 40(11): 803-809, 1985

Clinical comparison among interpulse membrane oxygenator teflon membrane oxygenator and shiley bubble oxygenator changes in blood components renin aldosterone system and renal function during extracorporeal circulation. Journal of the Japanese Association for Thoracic Surgery 34(2): 187-201, 1986

Description of a modified bubble-type pump-oxygenator; early experimental and clinical experience. Surgery 42(6): 996, 1957

Evaluation of a Disposable Bubble Oxygenator. Journal of Thoracic and Cardiovascular Surgery 50: 35-39, 1965

Evaluation of the efficiency and capacity of the bubble oxygenator. Arquivos Brasileiros de Cardiologia 33(2): 100-105, 1979

Comparison in children of the Peirce-General Electric membrane oxygenator with a bubble oxygenator. Mount Sinai Journal of Medicine new York 40(2): 146-152, 1973

A new efficient disposable rotating disc membrane oxygenator Vs Bentley bubble oxygenator. Surgical Forum 25(0): 132-134, 1974

Hematological advantage of a membrane oxygenator over a bubble oxygenator in long perfusions. Annals of Thoracic Surgery 41(3): 297-300, 1986

Clinical comparison between a stationary-screen oxygenator and a bubble-oxygenator in total body perfusion. Acta Chirurgica Scandinavica 122: 243-251, 1961

Comparative study of membrane oxygenator and bubble oxygenator in clinical open heart surgery. Circulation Suppl. 50(4-3): III201, 1974

Microembolism during cardiopulmonary bypass a comparison of bubble oxygenator with arterial line filter and membrane oxygenator alone. Perfusion 6(2): 99-104, 1991

New membrane oxygenator (LPM 50): influence on extravascular lung water and pulmonary function in comparison to bubble oxygenator. Journal of Thoracic and Cardiovascular Surgery 92(4): 798-800, 1986