Evaluation of a preparation depth controlling device: a pilot study



Evaluation of a preparation depth controlling device: a pilot study



Quintessence International 38(2): 135-142



To define the reproducibility and accuracy of the Prepometer device (Hager & Werken) and to correlate the measured electrical resistance with the remaining dentin thickness. In vivo standardized cavities were made on the buccal side in the cervical region of 12 intact teeth. Measurements with the Prepometer were completed before tooth extraction. After extraction, in vitro measurements of the remaining dentin thickness were performed using a microfocus-computerized tomography scanner. These in vitro scan data were compared with the in vivo measurements, and correlation coefficients calculated. The intra- and interinvestigator variability were defined, using a paired 2-tailed Student t test. The level of significance was set at 5%. Although both the intra- and interinvestigator variability scored well, there was no clear correlation between the Prepometer measurements and the remaining dentin thickness. Because the device determines the electrical resistance of the dentin, which is related to dentin permeability, real remaining dentin thickness cannot be measured. A reasonable safety zone (3 of 12 teeth scored false negative and 1 of 12 teeth scored false positive) in terms of remaining dentin thickness was observed. The Prepometer, a device developed to screen dentin-surface permeability by measuring its electrical resistance, was shown to be reproducible in its use. However, electrical resistance was shown not to correlate with dentin thickness. Although the Prepometer might help to estimate the risk of pulp injury after tooth preparation, its effectiveness still remains to be proven in a randomized clinical trial.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 048993857

Download citation: RISBibTeXText

PMID: 17263153


Related references

Evaluation of a device for objective determination of cervical consistency: a pilot study of device's validity on uterine specimens obtained by total abdominal hysterectomy for benign uterine disease. Journal of Perinatal Medicine 30(5): 364-366, 2002

Method and device for controlling the introduction depth of an injection needle. Official Gazette of the United States Patent & Trademark Office Patents 1264(3), 2002

Device for controlling the penetration depth of a needle, for application to an injection syringe. Official Gazette of the United States Patent & Trademark Office Patents 1244(2), 2001

A pilot evaluation study of high resolution digital thermal imaging in the assessment of burn depth. Burns 39(1): 76-81, 2013

Evaluation of a new intraoral paralleling device for creating guiding planes: a pilot study. Journal of Contemporary Dental Practice 11(1): E065-E072, 2010

Evaluation of Choroidal Thickness and Volume during the Third Trimester of Pregnancy using Enhanced Depth Imaging Optical Coherence Tomography: A Pilot Study. Journal of Clinical and Diagnostic Research 9(8): Nc08-Nc11, 2015

Histological and ultrastructural evaluation of the effects of a radiofrequency-based nonablative dermal remodeling device: a pilot study. Archives of Dermatology 140(2): 204-209, 2004

Analysis of the anesthesiologist's vigilance with an eye-tracking device. A pilot study for evaluation of the method under the conditions of a modern operating theatre. Der Anaesthesist 51(3): 180-186, 2002

Clinical evaluation of a positive pressure device to prevent central venous catheter occlusion: results of a pilot study. Clinical Journal of Oncology Nursing 5(6): 261-265, 2002

Evaluation of Veterinary Student Surgical Skills Preparation for Ovariohysterectomy Using Simulators: A Pilot Study. Journal of Veterinary Medical Education 43(2): 190-213, 2016

Preparation and evaluation of unitary doses of propafenone used in children with supraventricular tachycardia: a pilot study. European Review for Medical and Pharmacological Sciences 17(2): 189-194, 2013

X-ray microtomographic evaluation of the influence of two preparation types on marginal fit of CAD/CAM alumina copings: a pilot study. International Journal of Prosthodontics 25(2): 170-172, 2012

Preparation and clinical evaluation of succinylated collagen punctal plugs in dry eye syndrome: a pilot study. Ophthalmic Research 43(4): 185-192, 2010

Clinical evaluation of the efficacy and safety of a medical device in various forms containing Triticum vulgare for the treatment of venous leg ulcers - a randomized pilot study. Drug Design Development and Therapy 9: 2787-2792, 2015

Wedge osteotomy device including a guide for controlling osteotomy depth. Official Gazette of the United States Patent & Trademark Office Patents 1228(2), 1999