Evaluation of body weight as a predictive factor for transvenous ventricular defibrillation characteristics



Evaluation of body weight as a predictive factor for transvenous ventricular defibrillation characteristics



Europace 6(1): 21-24



To investigate the correlation between body weight and defibrillation threshold (DFT) for transvenous lead systems using a porcine model. Twenty-eight pigs were anaesthetised and DFTs assessed in single and dual coil configurations using a four-reversal binary search method. DFT was correlated with body weight in the RV --> Can and RV --> SVC + Can configurations. A Pearson correlation coefficient and a two-sided p-value were calculated. A positive correlation exists between body weight and DFT in RV --> Can (r=0.66, p<0.000) and RV --> SVC + Can (r=0.44, p=0.018). There is a significant correlation between body weight and DFT in swine. This tends to be greater in the two-electrode than in the three-electrode configuration. With these and previous human observations, one may predict a higher DFT in heavy individuals and make appropriate procedural adjustments.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 048994963

Download citation: RISBibTeXText

PMID: 14697722


Related references

Evaluation of body weight as a predictive factor for transvenous ventricular defibrillation characteristics. Europace 6(1): 21-24, 2004

Evaluation of ventricular vulnerability and safety during atrial defibrillation via implanted transvenous catheters in the sterile pericarditis model. Circulation 90(4 Part 2): I13, 1994

Transvenous-subcutaneous defibrillation leads: effect of transvenous electrode polarity on defibrillation threshold. Journal of Cardiovascular Electrophysiology 5(11): 912-918, 1994

Leakage of energy to the body surface during defibrillation shock by an implantable cardioverter-defibrillator (ICD) system--experimental evaluation during defibrillation shocks through the right ventricular lead and the subcutaneous active-can in canines. Japanese Circulation Journal 65(3): 219-225, 2001

Ventricular proarrhythmic effects of ventricular cycle length and shock strength in a sheep model of transvenous atrial defibrillation. Circulation 89(1): 413-422, 1994

Scaling current and energy with body weight: requirements for the transthoracic ventricular defibrillation of calves as they grow from 50 to 150 kg. Circulation 60(1): 187-195, 1979

Transvenous coronary sinus to right ventricular catheter defibrillation in man. Circulation 78(4 Part 2): II220, 1988

Multivariate analysis of factors predicting satisfactory defibrillation safety margin at transvenous defibrillation lead system implantation Can the occurrence of high defibrillation thresholds be predicted?. European Heart Journal 14(ABSTR Suppl. ): 410, 1993

Role of proximal electrode position in transvenous ventricular defibrillation. Annals of Biomedical Engineering 24(3): 418-423, 1996

Ventricular defibrillation with transvenous electrodes and sinusoidal waveforms of varying frequency. Circulation 94(8 Suppl. ): I438, 1996

Increase transvenous ventricular defibrillation threshold after endocardial pacemaker implantation. Circulation 94(8 Suppl. ): I439, 1996

Incidence of atrial fibrillation following ventricular defibrillation with transvenous lead systems in man. Journal of Cardiovascular Electrophysiology 3(5): 411-417, 1992

Transvenous cardioversion and defibrillation of ventricular tachyarrhythmias: current status and future directions. Pacing and Clinical Electrophysiology 8(5): 715-731, 1985

Redetection of Ventricular Fibrillation after a Failed First Shock in Transvenous Defibrillation Lead Systems. Journal of the American College of Cardiology 0(SPEC ISSUE): 316A, 1995

Effect of shock polarity on ventricular defibrillation threshold using a transvenous lead system. Journal Of The American College Of Cardiology. 24(4): 1069-1072, 1994