Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector



Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector



Medical Physics 30(2): 254-263



Our work is to investigate and understand the factors affecting the imaging performance of amorphous selenium (a-Se) flat-panel detectors for digital mammography. Both theoretical and experimental methods were developed to investigate the spatial frequency dependent detective quantum efficiency [DQE(f)] of a-Se flat-panel detectors for digital mammography. Since the K edge of a-Se is 12.66 keV and within the energy range of a mammographic spectrum, a theoretical model was developed based on cascaded linear system analysis with parallel processes to take into account the effect of K fluorescence on the modulation transfer function (MTF), noise power spectrum (NPS), and DQE(f) of the detector. This model was used to understand the performance of a small-area prototype detector with 85 microm pixel size. The presampling MTF, NPS, and DQE(f) of the prototype were measured, and compared to the theoretical calculation of the model. The calculation showed that K fluorescence accounted for a 15% reduction in the MTF at the Nyquist frequency (fNy) of the prototype detector, and the NPS at fNy was reduced to 89% of that at zero spatial frequency. The measurement of presampling MTF of the prototype detector revealed an additional source of blurring, which was attributed to charge trapping in the blocking layer at the interface between a-Se and the active matrix. This introduced a drop in both presampling MTF and NPS at high spatial frequency, and reduced aliasing in the NPS. As a result, the DQE(f) of the prototype detector at fNy approached 40% of that at zero spatial frequency. The measured and calculated DQE(f) using the linear system model have reasonable agreement, indicating that the factors controlling image quality in a-Se based mammographic detectors are fully understood, and the model can be used to further optimize detector imaging performance.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 049286671

Download citation: RISBibTeXText

PMID: 12607843

DOI: 10.1118/1.1538233


Related references

Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype. Medical Physics 27(3): 558-567, 2000

Amorphous selenium flat panel detectors for digital mammography: validation of a NPWE model observer with CDMAM observer performance experiments. Medical Physics 33(10): 3711-3722, 2006

Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy. Medical Physics 31(5): 1166-1175, 2004

Investigation of the effect of anode/filter materials on the dose and image quality of a digital mammography system based on an amorphous selenium flat panel detector. British Journal of Radiology 83(988): 290-295, 2010

Full-field digital mammography with amorphous silicon-based flat- panel detector: physical imaging characteristics and signal detection. Nihon Hoshasen Gijutsu Gakkai Zasshi 60(3): 399-405, 2004

Radiation exposure in full-field digital mammography with a flat-panel x-ray detector based on amorphous silicon in comparison with conventional screen-film mammography. Rofo 172(11): 940-945, 2001

X-ray imaging using amorphous selenium: Feasibility of a flat panel self-scanned detector for digital radiology. Medical Physics 22(10): 1595-1604, 1995

Evaluation of digital linear tomosynthesis imaging of total joint arthroplasty using an amorphous selenium flat-panel detector. Nihon Hoshasen Gijutsu Gakkai Zasshi 62(7): 1005-1012, 2006

Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system. Medical Physics 35(5): 1978-1987, 2008

Physical characterization of a prototype selenium-based full field digital mammography detector. Medical Physics 32(2): 588-599, 2005

Imaging and Dosimetric Study on Direct Flat-Panel Detector-Based Digital Mammography System. Journal of Medical Physics 43(4): 255-263, 2019

Radiation exposure in full-field digital mammography with a selenium flat-panel detector. Rofo 178(7): 693-697, 2006

Single-layer and dual-layer contrast-enhanced mammography using amorphous selenium flat panel detectors. Physics in Medicine and Biology 56(18): 5903-5923, 2011

Image quality and radiation dose on digital chest imaging: comparison of amorphous silicon and amorphous selenium flat-panel systems. Ajr. American Journal of Roentgenology 187(3): 630-637, 2006

Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience. Physics in Medicine and Biology 54(22): 6959-6978, 2009