Multilayer modeling of reflectance pulse oximetry



Multilayer modeling of reflectance pulse oximetry



IEEE Transactions on Bio-Medical Engineering 52(2): 153-159



A multilayer tissue description was employed in Monte Carlo simulations of reflectance pulse oximetry to study the impact of assumptions made in previous studies employing homogeneous tissue models. Simulation results with a discrete layer of arterial pulsatility were similar to previous studies employing homogenous tissue models. However, the relationship of normalized pulse amplitude to emitter-detector spacing reiterates that spacing has a significant impact on pulse oximetry function. The effect of melanin content as a thin, superficial absorber was also simulated, with results supporting the general clinical observation that skin shade need not substantially compromise pulse oximeter accuracy.

(PDF emailed within 0-6 h: $19.90)

Accession: 049636005

Download citation: RISBibTeXText

PMID: 15709652

DOI: 10.1109/TBME.2004.840188



Related references

The pulse in reflectance pulse oximetry: modeling and experimental studies. Journal of Clinical Monitoring and Computing 18(4): 289-299, 2005

Pulse oximetry in the air rescue service. 2: Methods of increasing the stability of pulse oximetry measurements--ECG-synchronized pulse oximetry and adhesive sensors. Anasthesiologie, Intensivmedizin, Notfallmedizin, Schmerztherapie 28(3): 174-178, 1993

Reflectance pulse oximetry in neonates. European Journal of Obstetrics & Gynecology & Reproductive Biology 61(2): 117-122, 1995

Reflectance pulse oximetry in fetal lambs. Pediatric Research 31(3): 266-269, 1992

Problems with forehead reflectance pulse oximetry. Respiratory Care 51(7): 715-716, 2006

Fetal reflectance pulse oximetry during labour. Zeitschrift fuer Geburtshilfe und Perinatologie 198(2): 67-71, 1994

Multi-wavelength reflectance pulse oximetry. Anesthesia and Analgesia 94(1 Suppl): S26-S30, 2002

Effect of location of the sensor on reflectance pulse oximetry. British Journal Of Obstetrics & Gynaecology. 104(8): 910-916, 1997

Reflectance pulse oximetry Two sensors compared in piglets. American Journal of Obstetrics & Gynecology 172(1 PART 2): 365, 1995

How tissue optics influences reflectance pulse oximetry. Advances in Experimental Medicine and Biology 388: 117-132, 1996

A novel photodiode for reflectance pulse oximetry in low-power applications. Conference Proceedings 2007: 2350-2353, 2007

Reflectance pulse oximetry measurements from the retinal fundus. IEEE Transactions on Bio-Medical Engineering 40(8): 817-823, 1993

Esophageal pulse oximetry utilizing reflectance photoplethysmography. IEEE Transactions on Bio-Medical Engineering 49(11): 1360-1368, 2002

Toward absolute reflectance oximetry: I. Theoretical consideration for noninvasive tissue reflectance oximetry. Advances in Experimental Medicine and Biology 248: 91-102, 1989

Multicenter study on the clinical value of fetal pulse oximetry. II. Compared predictive values of pulse oximetry and fetal blood analysis. The French Study Group on Fetal Pulse Oximetry. American Journal of Obstetrics and Gynecology 177(3): 593-598, 1997