Nonlinear finite element analysis of a splinted implant with various connectors and occlusal forces



Nonlinear finite element analysis of a splinted implant with various connectors and occlusal forces



International Journal of Oral and Maxillofacial Implants 18(3): 331-340



The aim of this study was to analyze the biomechanics in an implant/tooth-supported system under different occlusal forces with rigid and nonrigid connectors by adopting a nonlinear finite element (FE) approach. A model containing 1 Frialit-2 implant (placed in the second molar position) splinted to the mandibular second premolar was constructed. Nonlinear contact elements were used to simulate a realistic interface fixation between the implant body and abutment screw and the sliding keyway stress-breaker function. Stress distributions in the splinting system with rigid and nonrigid connectors were observed when vertical forces were applied to the tooth, pontic, implant abutment, or complete prosthesis in 10 simulated models. The displacement obtained from the natural tooth increased 11 times than that of the implant, and the peak stress values within the implant system (sigmaI, max) increased significantly when vertical forces acted only on the premolar of a fixed prosthesis with a rigid connector. The sigmaI, max values seen in the splinting prosthesis were not significantly different when vertical forces (50 N) were applied to the pontic, molar (implant) only, or the entire prosthesis, respectively, regardless of whether rigid or nonrigid connectors were used. Moreover, the peak stress values in the implant system and prosthesis were significantly reduced in single- or multiple-contact situations once vertical forces on the pontic were decreased. The compensatory mechanism between the implant components and keyway sliding function of the implant/tooth-supported prosthesis could be realistically simulated using nonlinear contact FE analysis. The nonrigid connector (keyway device) significantly exploited its function only when the splinting system received light occlusal forces. Minimization of the occlusal loading force on the pontic area through occlusal adjustment procedures to redistribute stress within the implant system in the maximum intercuspation position for an implant/tooth-supported prosthesis is recommended.

(PDF emailed within 1 workday: $29.90)

Accession: 049706795

Download citation: RISBibTeXText

PMID: 12814307



Related references

Distribution of occlusal forces during occlusal adjustment of dental implant prostheses: a nonlinear finite element analysis considering the capacity for displacement of opposing teeth and implants. International Journal of Oral and Maxillofacial Implants 27(2): 329-335, 2012

Influence of Implant Positions and Occlusal Forces on Peri-Implant Bone Stress in Mandibular Two-Implant Overdentures: A 3-Dimensional Finite Element Analysis. Journal of Oral Implantology 43(6): 419-428, 2017

Stress distribution in the peri-implant bone with splinted and non-splinted implants by in vivo loading data-based finite element analysis. Odontology 101(2): 222-226, 2015

Effect of crown to implant ratio and implant dimensions on periimplant stress of splinted implant-supported crowns: a finite element analysis. Implant Dentistry 22(4): 406-413, 2014

Three-dimensional finite element analysis of the splinted implant prosthesis in a reconstructed mandible. Journal of Advanced Prosthodontics 10(2): 138-146, 2018

Displacement and force distribution of splinted and tilted mandibular anterior teeth under occlusal loads: an in silico 3D finite element analysis. Progress in Orthodontics 17(1): 16, 2017

Evaluation of stress induced by implant type, number of splinted teeth, and variations in periodontal support in tooth-implant-supported fixed partial dentures: a non-linear finite element analysis. Journal of Periodontology 81(1): 121-130, 2010

Stress Distribution in Splinted and Unsplinted Implant-Supported Maxillary Overdentures: A 3D Finite Element Analysis. Implant Dentistry 27(1): 56-62, 2018

Effects of splinted prosthesis supported a wide implant or two implants: a three-dimensional finite element analysis. Clinical Oral Implants Research 16(4): 466-472, 2005

Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis. Journal of Healthcare Engineering 2018: 3163096, 2018

Stress-strain distribution at bone-implant interface of two splinted overdenture systems using 3D finite element analysis. Journal of Advanced Prosthodontics 5(3): 333-340, 2013

Should oral implants be splinted in a mandibular implant-supported fixed complete denture? A 3-dimensional-model finite element analysis. Journal of Prosthetic Dentistry 112(3): 508-514, 2015

Finite Element Analysis of Bone Stress for Miniscrew Implant Proximal to Root Under Occlusal Force and Implant Loading. Journal of Craniofacial Surgery 26(7): 2072-2076, 2016

A dynamic finite element analysis of stress distribution in bone tissue surrounding solely or splinted implant-borne fixed partial denture. Zhonghua Kou Qiang Yi Xue Za Zhi 47(7): 435-438, 2014

Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: a finite element analysis. Clinical Oral Implants Research 19(1): 107-117, 2007