Numerical determination of personal aerosol sampler aspiration efficiency



Numerical determination of personal aerosol sampler aspiration efficiency



Applied Occupational and Environmental Hygiene 18(4): 244-255



In this work the determination of the aspiration efficiency of personal aerosol samplers, commonly used in occupational exposure assessment, is investigated by means of CFD techniques. Specifically, it will be described a code to calculate the particle trajectories in a given flow field. At the present state the code considers only the effects of the mean flow field on the particle motion, whereas the turbulent diffusion effects are neglected. Comparisons with experimental measurements are also given in the framework of a research contract, supported by the European Community, with several experimental contributions from the participants. The main objective of the European research is to develop a new approach to experimentation with airborne particle flows, working on a reduced scale. This methodology has the advantage of allowing real-time aerosol determination and use of small wind tunnels, with a better experimental control. In this article we describe how the methodology has been verified using computational fluid dynamics. Experimental and numerical aspiration efficiencies have been compared and the influence of gravity and turbulence intensity in full and reduced scale has been investigated. The numerical techniques described here are in agreement with previous similar research and allow at least qualitative predictions of aspiration efficiency for real samplers, taking care of orientation from the incoming air flow. The major discrepancies among predicted and experimental results may be a consequence of bounce effects, which are very difficult to eliminate also by greasing the sampler surface.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 049720013

Download citation: RISBibTeXText

PMID: 12637235

DOI: 10.1080/10473220301397


Related references

The orientation-averaged aspiration efficiency of IOM-like personal aerosol samplers mounted on bluff bodies. Annals of Occupational Hygiene 48(1): 3-11, 2004

Development and evaluation of an ultrasonic personal aerosol sampler. Indoor Air 27(2): 409-416, 2017

Performance characteristics of the button personal inhalable aerosol sampler. Aihaj 61(3): 398-404, 2000

Evaluation of a personal and microenvironmental aerosol speciation sampler (PMASS). Research Report 2004(122): 1-22; Discussion 23-9, 2004

A collaborative European study of personal inhalable aerosol sampler performance. Annals of Occupational Hygiene 41(2): 135-153, 1997

Performance of the RespiCon personal aerosol sampler in forest products industry workplaces. Aiha Journal 63(3): 311-316, 2002

The particle size dependence of the collection efficiency of an environmental aerosol sampler. Atmospheric Environment 11(8): 677-681, 1977

Collection efficiency of a personal sampler for microbiological aerosols. American Industrial Hygiene Association Journal 52(12): 516-520, 1991

An aerosol sampler for determination of particle concentration as a function of size and time. Journal of the Air Pollution Control Association 17(4): 225-229, 1967

Correction of sampler-to-sampler comparisons based on aerosol size distribution. Journal of Occupational and Environmental Hygiene 4(4): 237-245, 2007

The Gillings Sampler--an electrostatic air sampler as an alternative method for aerosol in vitro exposure studies. Chemico-Biological Interactions 220: 158-168, 2014

Quantitating the efficiency of the coal mine personal respirable dust sampler for sampling oxide fumes. American Industrial Hygiene Association Journal 37(8): 459-463, 1976

The determination of quartz on personal sampler filters by x-ray diffraction. Annals of Occupational Hygiene 14(2): 65-70, 1971

Correlation between urinary 1-hydroxypyrene and ambient air pyrene measured with an inhalable aerosol sampler and a total dust sampler in an electrode paste plant. Science of the Total Environment 212(1): 59-67, 1998