Phase shift due to inversion recovery process and chemical shift effect in inversion recovery prepared gradient-echo magnetic resonance imaging



Phase shift due to inversion recovery process and chemical shift effect in inversion recovery prepared gradient-echo magnetic resonance imaging



Radiation Medicine 23(1): 56-60



The purpose of this study was to assess phase shift due to the inversion recovery process and the chemical shift effect in inversion recovery prepared gradient-echo magnetic resonance imaging. The signal intensities of three phantoms, composed of physiologic saline solution with Gd-DTPA, olive oil, and fat emulsion, were measured on a 1.5 Tesla unit. The sequence was single-shot two-dimensional. The parameters were as follows: TI 100-2500 msec at 100 msec intervals, TR 11.25 msec, TE 2.250 msec, 3.375 msec, and 4.500 msec. The k-space was filled with the centric view order. The signal intensity curves of the emulsion showed various patterns. At a TE of 2.250 msec, TI at the minimum value of signal intensity was 1500 msec. At a TE of 4.500 msec, TI at the minimum value was 500 msec. Up to a TI of 1000 msec, the signal intensity at a TE of 2.250 msec was stronger than that at a TE of 4.500 msec, and from a TI of 1000 msec, the signal intensity at a TE of 4.500 msec was stronger than that at a TE of 2.250 msec. We concluded that fat emulsion showed paradoxical phase shift.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 049910350

Download citation: RISBibTeXText

PMID: 15786753


Related references

Comparison of inversion recovery gradient echo with inversion recovery fast spin echo techniques for magnetic resonance imaging detection of navicular bone marrow lesions in horses. American Journal of Veterinary Research 74(2): 232-238, 2013

Fat suppression with short inversion time inversion-recovery and chemical-shift selective saturation: a dual STIR-CHESS combination prepulse for turbo spin echo pulse sequences. Journal of Magnetic Resonance Imaging 31(5): 1277-1281, 2010

Improved high-resolution pediatric vascular cardiovascular magnetic resonance with gadofosveset-enhanced 3D respiratory navigated, inversion recovery prepared gradient echo readout imaging compared to 3D balanced steady-state free precession readout imaging. Journal of Cardiovascular Magnetic Resonance 18(1): 74, 2016

Study of optimal flip angle for inversion-recovery gradient echo method in delayed contrast-enhanced cardiac magnetic resonance imaging. Nihon Hoshasen Gijutsu Gakkai Zasshi 69(4): 419-425, 2013

Oxygen-enhanced lung magnetic resonance imaging: influence of inversion pulse slice selectivity on inversion recovery half-Fourier single-shot turbo spin-echo signal. Japanese Journal of Radiology 29(4): 244-250, 2011

Real-time dynamics of an extravascular magnetic resonance contrast medium in acutely infarcted myocardium using inversion recovery and gradient-recalled echo-planar imaging. Investigative Radiology 27(11): 927-934, 1992

Detection of hypervascular hepatocellular carcinoma by dynamic magnetic resonance imaging with double-echo chemical shift in-phase and opposed-phase gradient echo technique: comparison with dynamic helical computed tomography imaging with double arterial phase. Journal of Computer Assisted Tomography 26(6): 981-987, 2002

Non-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses: comparison of imaging with the short tau inversion recovery method and the chemical shift selective method. Magnetic Resonance Imaging 33(1): 81-85, 2015

Magnetic resonance angiography by selective inversion recovery using a compact gradient echo sequence. Magnetic Resonance in Medicine 8(1): 96-103, 1988

Quantification of tissue gadolinium concentration using magnetic resonance imaging: comparison of ultrashort inversion time inversion recovery echoplanar and dynamic three-dimensional spoiled gradient-recalled approaches with in vitro measurements. Academic Radiology 3(Suppl. 2): S282-S285, 1996

The correlation between late gadolinium enhanced (LGE) magnetic resonance (MR), assessed with inversion-recovery gradient echo (IRGRE). European Journal of Heart Failure 8(3): 331; Author Reply 330, 2006

To Compare Diagnostic Ability of Contrast-Enhanced Three-Dimensional T1-SPACE with Three-Dimensional Fluid-Attenuated Inversion Recovery and Three-Dimensional T1-Magnetization Prepared Rapid Gradient Echo Magnetic Resonance Sequences in Patients of Meningitis. Journal of Neurosciences in Rural Practice 10(1): 48-53, 2019

Comparison of diffusion-weighted images using short inversion time inversion recovery or chemical shift selective pulse as fat suppression in patients with breast cancer. Japanese Journal of Radiology 27(4): 163-167, 2009

1H magnetic resonance imaging of human lung using inversion recovery turbo spin echo. Journal of Magnetic Resonance Imaging 11(6): 616-621, 2000

Dual-echo, chemical shift gradient-echo magnetic resonance imaging to quantify hepatic steatosis: Implications for living liver donation. Liver Transplantation 9(8): 851-856, 2003