+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Pulsed-laser crossed-beam thermal lens spectrometry for detection in a microchannel: influence of the size of the excitation beam waist



Pulsed-laser crossed-beam thermal lens spectrometry for detection in a microchannel: influence of the size of the excitation beam waist



Applied Spectroscopy 58(9): 1116-1121



Crossed-beam thermal lens spectrometry is especially designed for the detection of very small samples in capillary tubes and more generally in microfluidic devices. In this work, the effect of the size of the excitation beam with respect to the size of the sample microchannel has been investigated. Although the signal is inversely proportional to the size of the excitation waist into the sample, the use of large waists may provide greater sensitivities when short-pulse excitation lasers are used and allows easier optimization of the optical design. On the contrary, the use of small beam waists reduces the edge effects that can arise depending on the nature and thickness of the walls of the sample holder. Moreover, small beams provide better spatial resolution and have allowed the measurement of flow velocities as low as 1 mm s(-1).

(PDF emailed within 0-6 h: $19.90)

Accession: 050078276

Download citation: RISBibTeXText

PMID: 15479529

DOI: 10.1366/0003702041959424


Related references

Pulsed-laser mode-mismatched crossed-beam thermal lens spectrometry within a small capillary tube: effect of flow rate and beam offset on the photothermal signal. Spectrochimica Acta. Part A, Molecular and Biomolecular Spectroscopy 58(8): 1607-1613, 2002

Investigation of the optimum optical design for pulsed-laser crossed-beam thermal lens spectrometry in infinite and finite samples. Spectrochimica Acta. Part A, Molecular and Biomolecular Spectroscopy 60(4): 863-872, 2004

Time-resolved thermal lens spectroscopy with a single-pulsed laser excitation beam: an analytical model for dual-beam mode-mismatched experiments. Applied Optics 56(4): 999-1005, 2017

Determination of light-absorbing layers at inner capillary surface by cw excitation crossed-beam thermal-lens spectrometry. Talanta 78(3): 682-690, 2009

Continuous-wave-laser versus pulsed-laser excitation for crossed-beam photothermal detection in small volume applications: comparative features. Applied Spectroscopy 59(9): 1103-1108, 2007

Subfemtomole detection limit for amino acid determination with laser induced crossed beam thermal lens detection. Analytical Chemistry 59(23): 2803-2805, 1987

Pulsed laser thermal lens spectrometry of liquid samples using an optical fiber beam guide with interference orthogonal signal processing. Analytical Chemistry 58(8): 1706-1710, 1986

Pulsed-laser mode-mismatched dual-beam thermal lens spectrometry: comparison of the time-dependent and maximum signals with theoretical predictions. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy 54(1): 111-122, 1998

Signal optimisation in cw-laser crossed-beam photothermal spectrometry: influence of the chopping frequency, sample size and flow rate. Spectrochimica Acta. Part A, Molecular and Biomolecular Spectroscopy 61(13-14): 2849-2855, 2005

Probe-beam diffraction in a pulsed top-hat beam thermal lens with a mode-mismatched configuration. Applied Optics 38(24): 5241-5249, 2008

Crossed beam thermal lens detection for 025 mm diameter microbore liquid chromatography separation of 2 4 dinitrophenylhydrazones. 1987

Impact of Laser Beam Speckle Structure on Crossed Beam Energy Transfer via Beam Deflections and Ponderomotive Self-Focusing. Physical Review Letters 118(5): 055002-055002, 2017

Monitoring supercritical fluid extraction by thermal lens spectrometry with pulsed laser excitation. Analytica Chimica Acta 390(1-3): 163-173, May 19, 1999

Crossed beam thermal lens. Abstracts of Papers American Chemical Society 193, 1987

Pulsed laser desorption with resonant two photon ionization detection in supersonic beam mass spectrometry. Analytical Chemistry 58(7): 1299-1303, 1986