Specificity of atrial mode switching in detecting atrial fibrillation episodes: roles of length and contiguity



Specificity of atrial mode switching in detecting atrial fibrillation episodes: roles of length and contiguity



Pacing and Clinical Electrophysiology 28(Suppl. 1): S47-S49



The number of automatic mode switch (AMS) has been used to measure the efficacy of atrial pacing in limiting atrial fibrillation (AF). We investigated the impact of length and contiguity on the specificity of AMS in detecting AF episodes in 24 recipients of dual chamber pacemakers with sick sinus syndrome and paroxysmal AF. An AMS algorithm and intracardiac electrogram recordings (IEGM) were activated in all patients to distinguish true arrhythmic events from unnecessary AMS. The length of AMS and the contiguity, that is, the probability of occurrence of another AMS within 5 minutes before or after AMS were examined to increase the specificity of the AMS. During a mean follow-up of 5 +/- 3 months, 250 AMS were collected. The IEGM analysis confirmed a true AF episode in 193 of 250 AMS (77.2%). Using the contiguity criterion, 47 of 57 (82.5%) inappropriate AMS episodes were isolated (there were no other AMS within 5 minutes), whereas 54 of 193 (27.9%) appropriate AMS episode were isolated. Adopting both length and contiguity criteria the specificity of AMS in detecting true AF episodes increased from 77.2% to 93.2% at the cost of 11.9% loss of original sensitivity. Combining the length and contiguity criteria, we were able to improve the specificity of the AMS in the detection of AF.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 050358279

Download citation: RISBibTeXText

PMID: 15683523

DOI: 10.1111/j.1540-8159.2005.00031.x


Related references

Atrial pacing reduces mode switching episodes in patients with paroxysmal atrial fibrillation. European Heart Journal 20(ABSTR SUPPL ): 452, 1999

Predictors of chronic atrial fibrillation following atrioventricular node ablation and DDDR mode-switching pacing for paroxysmal atrial fibrillation. European Heart Journal 20(ABSTR SUPPL ): 213, 1999

Improved efficacy of mode switching during atrial fibrillation using automatic atrial sensitivity adjustment. Pacing and Clinical Electrophysiology 22(1 Pt 1): 17-25, 1999

Programmed atrial sensitivity: a critical determinant in atrial fibrillation detection and optimal automatic mode switching. Pacing and Clinical Electrophysiology 21(11 Pt 2): 2214-2219, 1998

Verification of pacemaker automatic mode switching for the detection of atrial fibrillation and atrial tachycardia with Holter recording. Europace 8(11): 950-961, 2006

The Connexin40A96S mutation from a patient with atrial fibrillation causes decreased atrial conduction velocities and sustained episodes of induced atrial fibrillation in mice. Journal of Molecular and Cellular Cardiology 65: 19-32, 2014

Effects of verapamil and ibutilide on atrial fibrillation cycle length, post-fibrillation atrial refractoriness and early atrial fibrillation recurrences in humans. European Heart Journal 22(Abstract Suppl.): 326, 2001

Relevance of electrical remodeling in human atrial fibrillation: results of the Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial mechanisms of atrial fibrillation study. Circulation. Arrhythmia and Electrophysiology 5(4): 626-631, 2012

Prospective, randomized study of atrioventricular ablation and mode-switching, dual chamber pacemaker implantation versus medical therapy in drug-resistant paroxysmal atrial fibrillation. The PAF study. Paroxysmal Atrial Fibrillation. Europace 1(1): 15-19, 2001

Prediction of stroke risk in atrial fibrillation, prevention of stroke in atrial fibrillation, and the impact of long-term monitoring for detecting atrial fibrillation. Current Atherosclerosis Reports 13(4): 290-297, 2011

Early delivery of automatic atrial antitachycardia pacing is effective in termination of atrial fibrillation episodes and atrial tachyarrhythmias. Circulation 108(17 Suppl.): IV-708, October 28, 2003

Atrial fibrillation cycle length and atrial size in horses with and without recurrence of atrial fibrillation after electrical cardioversion. Journal of Veterinary Internal Medicine 28(2): 624-629, 2015

Localized reentrant tachycardia in the aorta contiguity region mimicking perimitral atrial flutter in the context of atrial fibrillation ablation. Heart and Vessels 28(4): 546-549, 2014

Modes of onset of spontaneous episodes of atrial fibrillation Implications for the prevention of atrial fibrillation by pacing. Daubert, J C , Prystowsky, E N , Ripart, A Prevention of tachyarrhythmias with cardiac pacing : 53-65, 1997

Left atrial reverse remodeling and prevention of progression of atrial fibrillation with atrial resynchronization device therapy utilizing dual-site right atrial pacing in patients with atrial fibrillation refractory to antiarrhythmic drugs or catheter ablation. Journal of Interventional Cardiac Electrophysiology 40(3): 245-254, 2015