EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging



Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging



Annals of Nuclear Medicine 20(6): 409-416



Pinhole SPECT which permits in vivo high resolution 3D imaging of physiological functions in small animals facilitates objective assessment of pharmaceutical development and regenerative therapy in pre-clinical trials. For handiness and mobility, the miniature size of the SPECT system is useful. We developed a small animal SPECT system based on a compact high-resolution gamma camera fitted to a pinhole collimator and an object-rotating unit. This study was aimed at evaluating the basic performance of the detection system and the feasibility of small animal SPECT imaging. The gamma camera consists of a 22 x 22 pixellated scintillator array of 1.8 mm x 1.8 mm x 5 mm NaI(Tl crystals with 0.2-mm gap between the crystals coupled to a 2" flat panel position-sensitive photomultiplier tube (Hamamatsu H8500) with 64 channels. The active imaging region of the camera was 43.8 mm x 43.8 mm. Data acquisition is controlled by a personal computer (Microsoft Windows) through the camera controller. Projection data over 360 degrees for SPECT images are obtained by synchronizing with the rotating unit. The knife-edge pinhole collimators made of tungsten are attached on the camera and have 0.5-mm and 1.0-mm apertures. The basic performance of the detection system was evaluated with 99mTc and 201Tl solutions. Energy resolution, system spatial resolution and linearity of count rate were measured. Rat myocardial perfusion SPECT scans were sequentially performed following intravenous injection of 201TlCl. Projection data were reconstructed using a previously validated pinhole 3D-OSEM method. The energy resolution at 140 keV was 14.8% using a point source. The system spatial resolutions were 2.8-mm FWHM and 2.5-mm FWHM for 99mTc and 201Tl line sources, respectively, at 30-mm source distance (magnification factor of 1.3) using a 1.0-mm pinhole. The linearity between the activity and count rate was good up to 10 kcps. In a rat study, the left ventricular walls were clearly visible in all scans. We developed a compact SPECT system using compact gamma camera for small animals and evaluated basic physical performances. The present system may be of use for quantitation of biological functions such as myocardial blood flow in small animals.

(PDF emailed within 0-6 h: $19.90)

Accession: 050904862

Download citation: RISBibTeXText

PMID: 16922469

DOI: 10.1007/bf03027376



Related references

A review of small animal imaging planar and pinhole spect Gamma camera imaging. Veterinary Radiology & Ultrasound 46(2): 162-170, 2005

A clinical gamma camera-based pinhole collimated system for high resolution small animal SPECT imaging. Brazilian Journal of Medical and Biological Research 43(12): 1160-1166, 2011

Optimized Collimator Designs for Small Animal SPECT Imaging With a Compact Gamma Camera. Conference Proceedings 2: 1780-1782, 2007

Development of a high-resolution pinhole SPECT system using dual-head gamma camera for small animal studies. Kaku Igaku. Japanese Journal of Nuclear Medicine 35(9): 901-907, 1999

Application of an ultra high-resolution pinhole SPECT system based on a conventional camera for small animal imaging. Journal of Nuclear Medicine 42(5 Supplement): 54P-55P, 2001

A novel multi-pinhole/CCD-coupled CsI crystal gamma camera for fully 3D muSPECT/muCT small-animal imaging. Journal of Nuclear Medicine 44(5 Supplement): 161P, 2003

Phantom experiments on a PSAPD-based compact gamma camera with submillimeter spatial resolution for small animal SPECT. IEEE Transactions on Nuclear Science 57(5): 2518-2523, 2011

Sensitivity of planar and SPECT imaging of 111In with a small animal gamma camera. Journal of Nuclear Medicine 44(5 Supplement): 288P-289P, 2003

Performance evaluation of compact detectors based on new pixellated NaI crystal arrays for high-resolution small animal imaging. Journal of Nuclear Medicine 43(5 Supplement): 59P, 2002

Experimental task-based optimization of a four-camera variable-pinhole small-animal SPECT system. Proceedings of Spie--the International Society for Optical Engineering 5749(): -, 2005

Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT-CT scanners. Physics in Medicine and Biology 53(15): 4185-4201, 2008

Small animal imaging with multi-pinhole SPECT. Methods 48(2): 83-91, 2009

Temperature dependent operation of PSAPD-based compact gamma camera for SPECT imaging. IEEE Transactions on Nuclear Science 58(5): 2169-2174, 2011

High resolution pinhole SPECT for small animal imaging. Journal of Nuclear Medicine 34(5 SUPPL ): 9P, 1993

A prototype instrument for single pinhole small animal adaptive SPECT imaging. Medical Physics 35(5): 1912-1925, 2008