Utilization of low-profile intra-aortic balloon catheters inserted by the sheathless technique in acute cardiac patients: clinical efficacy with a very low complication rate



Utilization of low-profile intra-aortic balloon catheters inserted by the sheathless technique in acute cardiac patients: clinical efficacy with a very low complication rate



Clinical Cardiology 27(11): 600-604



Initial intra-aortic balloon pump (IABP) catheters were of large caliber and their utilization resulted in a high incidence of complications, including limb ischemia, bleeding and thrombosis, peripheral neurologic sequelae, and infection. Despite eventual decrease in the size of IABP catheters, the complication rate has remained high. The study was undertaken to determine whether use of recently available low-profile IABP catheters would result in a lower incidence of vascular and bleeding complications. We prospectively evaluated the incidence of complications when consecutively using the low-profile (8F) IABP catheter inserted mostly sheathlessly in 161 acute cardiac patients between January 1, 2000 and April, 2003. Complications encountered included mild transient limb ischemia in two patients (1.2%), minor bleeding episodes in four patients (2.4%), one major puncture site bleeding (0.6%), and a pseudoaneurysm treated percutaneously in two patients (1.2%). Two patients (1.2%) suffered limb ischemia due to embolization or local thrombosis requiring vascular intervention. These complications were milder and their incidence remarkably lower than those reported previously when IABP catheters larger than 8F were used. Utilization of low-profile IABP 8F catheters in a sheathless technique entails an exceedingly low complication rate despite an acute presentation, intense anticoagulant and antiaggregant therapy, frequent comorbidity, advanced age, severe coronary disease, and reduced cardiac function in a large proportion of treated patients.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 050921545

Download citation: RISBibTeXText

PMID: 15562927

DOI: 10.1002/clc.4960271104


Related references

Clinical characteristics and outcomes of acute coronary syndrome patients with intra-aortic balloon pump inserted in intensive cardiac care unit of a tertiary clinic. Turk Kardiyoloji Dernegi Arsivi 46(1): 10-17, 2018

Technique of implantation and removal of balloon catheters for the intra-aortic balloon counter pulsation. Journal of Cardiovascular Surgery 22(1): 35-40, 1981

Safety and efficacy of transbrachial intra-aortic balloon pumping with the use of 7-Fr catheters in patients undergoing coronary bypass surgery. Interactive Cardiovascular and Thoracic Surgery 9(1): 135-137, 2009

Clinical outcomes of the intra-aortic balloon pump for resuscitated patients with acute myocardial infarction complicated by cardiac arrest. Journal of Cardiology 67(1): 57-63, 2016

Clinical efficacy of intra-aortic balloon pumping in treating patients with acute myocardial infarction with left main coronary artery disease. Zhonghua Yi Xue Za Zhi 92(38): 2685-2688, 2012

Comparison of complication rates of Hickman(®) catheters versus peripherally inserted central catheters in patients with acute myeloid leukemia undergoing induction chemotherapy. Leukemia and Lymphoma 54(6): 1263-1267, 2013

Clinical experience with a per cutaneously inserted intra aortic balloon. Artificial Organs 5A: 9, 1981

Cardiovascular devices; reclassification of intra-aortic balloon and control systems for acute coronary syndrome, cardiac and non-cardiac surgery, or complications of heart failure; effective date of requirement for premarket approval for intra-aortic balloon and control systems for septic shock or pulsatile flow generation. Final order. Federal Register 78(250): 79300-3, 2014

Clinical significance of oxygen consumption in the immediate postoperative period in cardiosurgery patients during intra-aortic balloon counterpulsation in the evaluation of the results of treatment of acute cardiac insufficiency. Anesteziologiia i Reanimatologiia .(4): 60-62, 1984

eComment. Sheathless intra-aortic balloon pump insertion. Interactive Cardiovascular and Thoracic Surgery 15(1): 139-140, 2012

Physical and clinical aspects of intra-aortic balloon pump catheters. Maccioli, G A Intra-aortic balloon pump therapy: 51-56, 1997

5-Fr sheathless transradial cardiac catheterization using conventional catheters and balloon assisted tracking; a new approach to downsizing. Cardiovascular Revascularization Medicine 18(1): 28-32, 2016

Efficacy and safety of peripherally inserted central venous catheters in acute cardiac care management. Journal of Vascular Access 19(5): 455-460, 2018

Clinical trial with a percutaneously inserted intra-aortic balloon pump: a wider spectrum of patient application. Thoracic and Cardiovascular Surgeon 28(3): 197-199, 1980

Clinical results of intra aortic balloon pumping in 51 patients following cardiac surgery. Journal of the Japanese Association for Thoracic Surgery 33(3): 291-297, 1985