+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Validity and reliability of existing and modified clinical methods of measuring femoral and tibiofibular torsion in healthy subjects: use of different reference axes may improve reliability



Validity and reliability of existing and modified clinical methods of measuring femoral and tibiofibular torsion in healthy subjects: use of different reference axes may improve reliability



Clinical Anatomy 18(1): 46-55



Previous studies have evaluated reliability and validity of clinical measurements of femoral and tibiofibular torsion, however, the results are conflicting, warranting an alternative method. The authors developed modified methods of measuring femoral and tibiofibular torsion using different reference axes, and validity and reliability of the modified and existing methods were examined in healthy subjects. Reference values were established using magnetic resonance imaging (MRI) for the validity study. There were significant differences between all clinical methods and corresponding MRI outcomes (P <0.05), whereas Pearson's correlation coefficients between the clinical methods and MRI ranged from 0.67-0.92. For modified methods, intraclass correlation coefficients were 0.89-0.97, whereas those of existing methods were 0.75-0.81. Modified methods were more precise, with standard error of measurements (SEM) of 1.5-2.9 degrees , compared to existing methods (SEM=4.0-5.1 degrees). These results indicate that clinical methods available currently do not accurately measure true torsion of the femur and tibia. Nevertheless, the clinical methods may be useful for screening and descriptive purposes as indices of true torsion, and use of different reference axes could improve their reliability.

(PDF emailed within 0-6 h: $19.90)

Accession: 050927226

Download citation: RISBibTeXText

PMID: 15597368

DOI: 10.1002/ca.20050


Related references

Reliability and validity of measuring respiration movement using a wearable strain sensor in healthy subjects. Journal of Physical Therapy Science 29(9): 1543-1547, 2017

A modified method for measuring uniocular fields of fixation: reliability in healthy subjects and in patients with Graves orbitopathy. Archives of Ophthalmology 123(3): 356-362, 2005

Measuring clinical status in cystic fibrosis: internal validity and reliability of a modified NIH score. Pediatric Pulmonology 17(2): 86-96, 1994

Reliability and longitudinal validity of computer-assisted methods for measuring joint damage progression in subjects with rheumatoid arthritis. Journal of Rheumatology 40(1): 23-29, 2013

Femoral torsion: reliability and validity of the trochanteric prominence angle test. Hip International 22(5): 534-538, 2013

Reliability and validity of a Coda Motion 3-D Analysis system for measuring cervical range of motion in healthy subjects. Journal of Electromyography and Kinesiology 38: 56-66, 2017

A new method using ultrasound for measuring femoral anteversion (torsion): technique and reliability. British Journal of Radiology 60(714): 519-523, 1987

Clinical evaluation in prosthodontics: practical methods to improve validity and reliability at the undergraduate level. Journal of Prosthetic Dentistry 75(6): 675-680, 1996

Measuring technology self efficacy: reliability and construct validity of a modified computer self efficacy scale in a clinical rehabilitation setting. Disability and Rehabilitation 34(3): 220-227, 2012

A new concept of estimating tibiofibular torsion: an in vivo reliability study. Journal of Orthopaedic and Sports Physical Therapy 33(2): 85-90, 2003

Validity and reliability of measuring femoral anteversion and neck-shaft angle in patients with cerebral palsy. Journal of Bone and Joint Surgery. American Volume 92(5): 1195-1205, 2010

The validity and reliability of noninvasive methods for measuring kyphosis. Journal of Spinal Disorders and Techniques 27(6): E212-E218, 2014

Validity and reliability of two protocols for measuring Reachable Workspace Volume in able-bodied and stroke subjects. Technology and Health Care 24(4): 513-521, 2017

The reliability and validity of the physiological cost index in healthy subjects while walking on 2 different tracks. Archives of Physical Medicine and Rehabilitation 86(10): 2041-2046, 2005

Validity and reliability of assessing diaphragmatic mobility by area on X-rays of healthy subjects. Jornal Brasileiro de Pneumologia 44(3): 220-226, 2018