+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Variations in lithium target thickness and proton energy stability for the near-threshold 7Li(p,n)7Be accelerator-based BNCT



Variations in lithium target thickness and proton energy stability for the near-threshold 7Li(p,n)7Be accelerator-based BNCT



Physics in Medicine and Biology 52(3): 645-658



The usable range of thickness for the solid lithium target in the accelerator-based neutron production for BNCT via the near-threshold (7)Li(p,n)(7)Be reaction was investigated. While the feasibility of using a (7)Li-target with thickness equal to that which is required to slow down a mono-energetic 1.900 MeV incident proton to the 1.881 MeV threshold of the (7)Li(p,n)(7)Be reaction (i.e., t(min) = 2.33 microm) has already been demonstrated, dosimetric properties of neutron fields from targets greater than t(min) were assessed as thicker targets would last longer and offer more stable neutron production. Additionally, the characteristics of neutron fields generated by (7)Li(p,n)(7)Be for Gaussian incident protons with mean energy of 1.900 MeV were evaluated at a (7)Li-target thickness t(min). The main evaluation index applied in this study was the treatable protocol depth (TPD) which corresponds to the depth in an irradiated medium that satisfies the requirements of the adapted dose protocol. A maximum TPD (TPD(max)) was obtained for each irradiation condition from the relationship between the TPD and the thickness of boron dose enhancer (BDE) used. For a mono-energetic 1.900 MeV proton beam, the deepest TPD(max) of 3.88 cm was attained at the (7)Li-target thickness of t(min) and a polyethylene BDE of 1.10 cm. When the intended TPD for a BNCT clinical treatment is shallower than the deepest TPD(max), the usable (7)Li-target thickness would be between t(min) and an upper limit t(upper) whose value depends on the BDE thickness used. In terms of the effect of stability of the incident proton energy, Gaussian incident proton energies stable to within +/-10 keV of 1.900 MeV were found to be feasible for the neutron production via the near-threshold (7)Li(p,n)(7)Be reaction for BNCT provided that a suitable BDE is used.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 050934016

Download citation: RISBibTeXText

PMID: 17228111

DOI: 10.1088/0031-9155/52/3/008


Related references

Characteristics of proton beam scanning dependent on Li target thickness from the viewpoint of heat removal and material strength for accelerator-based BNCT. Applied Radiation and Isotopes 67(2): 259-265, 2009

What is the best proton energy for accelerator-based BNCT using the 7Li(p,n)7Be reaction?. Medical Physics 27(5): 1113-1118, 2000

An experimental study of the moderator assembly for a low-energy proton accelerator neutron irradiation facility for BNCT. Basic Life Sciences 54: 271-280, 1990

Characteristics of BDE dependent on 10B concentration for accelerator-based BNCT using near-threshold 7Li(p,n)7Be direct neutrons. Applied Radiation and Isotopes 61(5): 875-879, 2004

Lithium target performance evaluation for low-energy accelerator-based in vivo measurements using gamma spectroscopy. Applied Radiation and Isotopes 58(3): 321-331, 2003

Optimization of the photoneutron target geometry for e-accelerator based BNCT. Electronic Physician 9(6): 4590-4596, 2017

High-power electron beam tests of a liquid-lithium target and characterization study of (7)Li(p,n) near-threshold neutrons for accelerator-based boron neutron capture therapy. Applied Radiation and Isotopes 88: 238-242, 2014

Near-threshold (7)Li(p,n)(7)Be neutrons on the practical conditions using thick Li-target and Gaussian proton energies for BNCT. Applied Radiation and Isotopes 88: 221-224, 2014

Be target development for the accelerator-based SPES-BNCT facility at INFN Legnaro. Applied Radiation and Isotopes 67(7-8 Suppl): S270-S273, 2009

A practical target system for accelerator-based BNCT which may effectively double the dose rate. Medical Physics 25(6): 894-896, 1998

Design of photon converter and photoneutron target for High power electron accelerator based BNCT. Applied Radiation and Isotopes 106: 45-48, 2015

Design study on an accelerator-based facility for BNCT and low energy neutron source. Progress in Nuclear Energy 37(1-4): 321-326, 2000

TPD-based evaluation of near threshold mono-energetic proton energies for the (7)Li(p,n)(7)Be production of neutrons for BNCT. Physics in Medicine and Biology 51(16): 4095-4109, 2006

Dosimetric performance evaluation regarding proton beam incident angles of a lithium-based AB-BNCT design. Radiation Protection Dosimetry 161(1-4): 403-409, 2014

Application of a Bonner sphere spectrometer for the determination of the angular neutron energy spectrum of an accelerator-based BNCT facility. Applied Radiation and Isotopes 88: 216-220, 2014