Volume registration using needle paths and point landmarks for evaluation of interventional MRI treatments



Volume registration using needle paths and point landmarks for evaluation of interventional MRI treatments



IEEE Transactions on Medical Imaging 22(5): 653-660



We created a method for three-dimensional (3-D) registration of medical images (e.g., magnetic resonance imaging (MRI) or computed tomography) to images of physical tissue sections or to other medical images and evaluated its accuracy. Our method proved valuable for evaluation of animal model experiments on interventional-MRI guided thermal ablation and on a new localized drug delivery system. The method computes an optimum set of rigid body registration parameters by minimization of the Euclidean distances between automatically chosen correspondence points, along manually selected fiducial needle paths, and optional point landmarks, using the iterative closest point algorithm. For numerically simulated experiments, using two needle paths over a range of needle orientations, mean voxel displacement errors depended mostly on needle localization error when the angle between needles was at least 20 degrees. For parameters typical of our in vivo experiments, the mean voxel displacement error was < 0.35 mm. In addition, we determined that the distance objective function was a useful diagnostic for predicting registration quality. To evaluate the registration quality of physical specimens, we computed the misregistration for a needle not considered during the optimization procedure. We registered an ex vivo sheep brain MR volume with another MR volume and tissue section photographs, using various combinations of needle and point landmarks. Mean registration error was always < or = 0.54 mm for MR-to-MR registrations and < or = 0.52 mm for MR to tissue section registrations. We also applied the method to correlate MR volumes of radio-frequency induced thermal ablation lesions with actual tissue destruction. In this case, in vivo rabbit thigh volumes were registered to photographs of ex vivo tissue sections using two needle paths. Mean registration errors were between 0.7 and 1.36 mm over all rabbits, the largest error less than two MR voxel widths. We conclude that our method provides sufficient spatial correspondence to facilitate comparison of 3-D image data with data from gross pathology tissue sections and histology.

(PDF emailed within 0-6 h: $19.90)

Accession: 050957856

Download citation: RISBibTeXText

PMID: 12846434

DOI: 10.1109/TMI.2003.812246



Related references

Point-to-point registration with mandibulo-maxillary splint in open and closed jaw position. Evaluation of registration accuracy for computer-aided surgery of the mandible. Journal of Cranio-Maxillo-Facial Surgery 40(7): 592-598, 2013

Anatomical landmarks for point-matching registration in image-guided neurosurgery. International Journal of Medical Robotics + Computer Assisted Surgery 10(1): 55-64, 2014

Elastic registration of electrophoresis images using intensity information and point landmarks. Pattern Recognition 37(5): 1035-1048, 2004

Accurate localization of needle entry point in interventional MRI. Journal of Magnetic Resonance Imaging 12(4): 645-649, 2000

Measurement of the clenching force during needle point registration in dentulous patients. Deutsche Stomatologie 41(4): 117-120, 1991

Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer. IEEE Transactions on Medical Imaging 22(4): 515-525, 2003

In vitro evaluation of the influence of needle gauge and point design on needle deviation during regional anesthesia. Anesthesia & Analgesia 78(2 SUPPL ): ABSTRACT S214, 1994

Point-to-volume registration of prostate implants to ultrasound. Medical Image Computing and Computer-Assisted Intervention 14(Pt 2): 615-622, 2011

Rigid-body point-based registration: The distribution of the target registration error when the fiducial registration errors are given. Medical Image Analysis 15(4): 397-413, 2012

Prospective evaluation of point-of-care ultrasound for pre-procedure identification of landmarks versus traditional palpation for lumbar puncture. World Journal of Emergency Medicine 7(3): 173-177, 2016

An evaluation of a combined spinal/epidural needle set utilising a 26-gauge, pencil point spinal needle for caesarean section. Anaesthesia 47(11): 990-992, 1992

Evaluation of bone surface registration applying a micro-needle array. Journal of Clinical Periodontology 34(11): 991-997, 2007

Taper and volume responses of Douglas-fir to sulfur treatments for control of Swiss needle cast in the Coast Range of Oregon. Western Journal of Applied Forestry 23(3): 142-148, 2008

The influence of artificial paths and landmarks on the foraging behavior of Norway rats (Rattus norvegicus). Animal Learning and Behavior 26(1): 76-84, 1998

Initial evaluation of subcutaneous daclizumab treatments for noninfectious uveitis: a multicenter noncomparative interventional case series. Ophthalmology 112(5): 764-770, 2005