+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Wind-velocity lidar measurements by use of a Mach-Zehnder interferometer, comparison with a Fabry-Perot interferometer



Wind-velocity lidar measurements by use of a Mach-Zehnder interferometer, comparison with a Fabry-Perot interferometer



Applied Optics 43(1): 173-182



We present the first wind-velocity profiles obtained with a direct-detection Doppler lidar that uses a Mach-Zehnder interferometer (MZI) as spectral discriminator. The measurements were performed in the lower stratosphere, between 10 and 40 km in altitude, at the Observatoire de Haute Provence (OHP), France, during nighttime. They are in excellent agreement with those obtained simultaneously and independently with the already validated double Fabry-Perot interferometer (FPI) of the OHP Doppler lidar (mean difference lower than the combined standard deviation). A statistical analysis shows that the random error obtained with this experimental MZI is 1.94 times the Cramer-Rao lower bound and is approximately half of that given by the FPI (both operating in photometric mode). Nevertheless, the present MZI measurements are sensitive to the presence of atmospheric particles and need an additional correction, whereas the OHP FPI is designed to be insensitive to particulate scattering.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 050984628

Download citation: RISBibTeXText

PMID: 14714660

DOI: 10.1364/ao.43.000173


Related references

Simultaneous measurements of particle backscattering and extinction coefficients and wind velocity by lidar with a Mach-Zehnder interferometer: principle of operation and performance assessment. Applied Optics 42(6): 1101-1114, 2003

Direct-detection Doppler wind measurements with a Cabannes-Mie lidar: a. Comparison between iodine vapor filter and Fabry-Perot interferometer methods. Applied Optics 46(20): 4434-4443, 2007

Polar cap mesosphere wind observations: comparisons of simultaneous measurements with a Fabry-Perot interferometer and a field-widened Michelson interferometer. Applied Optics 39(24): 4284-4291, 2008

Mach-zehnder interferometer as a spectral analyzer for molecular Doppler wind lidar. Applied Optics 40(3): 391-399, 2008

Fringe-imaging Mach-Zehnder interferometer as a spectral analyzer for molecular Doppler wind lidar. Applied Optics 41(3): 503-510, 2002

Vertical wind profiling with fiber-Mach-Zehnder-interferometer-based incoherent Doppler lidar. Optics and Lasers in Engineering 121: 61-65, 2019

Fabry-Perot interferometer based Mie Doppler lidar for low tropospheric wind observation. Applied Optics 46(29): 7120-7131, 2007

All-fiber upconversion high spectral resolution wind lidar using a Fabry-Perot interferometer. Optics Express 24(17): 19322-19336, 2016

Stratospheric temperature measurement with scanning Fabry-Perot interferometer for wind retrieval from mobile Rayleigh Doppler lidar. Optics Express 22(18): 21775-21789, 2014

Interferometric filters for spectral discrimination in high-spectral-resolution lidar: performance comparisons between Fabry-Perot interferometer and field-widened Michelson interferometer. Applied Optics 52(32): 7838-7850, 2013

Fabry-Perot-interferometer imaging system for thermospheric temperature and wind measurements. Applied Optics 19(13): 2206-2209, 1980

A comparison of vertical thermospheric winds from Fabry-Perot interferometer measurements over a 50 km baseline. Advances in Space Research 26(6): 985-988, 2000

Coincident Thermos3pheric Wind Measurements using ground-based Doppler Asymmetric Spatial Heterodyne DASH and Fabry?Perot Interferometer FPI instruments. Journal of Atmospheric and Solar-Terrestrial Physics 86: 92-98, 2012

Investigation of the influence of spatial coherence of a broad-area laser diode on the interference fringe system of a Mach-Zehnder interferometer for highly spatially resolved velocity measurements. Applied Optics 44(9): 1582-1590, 2005

Measurement method of high spectral resolution lidar with a multimode laser and a scanning Mach-Zehnder interferometer. Applied Optics 56(21): 5990-5995, 2017