EurekaMag.com logo
+ Site Statistics
References:
53,623,987
Abstracts:
29,492,080
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

4D-CT Lung registration using anatomy-based multi-level multi-resolution optical flow analysis and thin-plate splines



4D-CT Lung registration using anatomy-based multi-level multi-resolution optical flow analysis and thin-plate splines



International Journal of Computer Assisted Radiology and Surgery 9(5): 875-889



The accuracy of 4D-CT registration is limited by inconsistent Hounsfield unit (HU) values in the 4D-CT data from one respiratory phase to another and lower image contrast for lung substructures. This paper presents an optical flow and thin-plate spline (TPS)-based 4D-CT registration method to account for these limitations. The use of unified HU values on multiple anatomy levels (e.g., the lung contour, blood vessels, and parenchyma) accounts for registration errors by inconsistent landmark HU value. While 3D multi-resolution optical flow analysis registers each anatomical level, TPS is employed for propagating the results from one anatomical level to another ultimately leading to the 4D-CT registration. 4D-CT registration was validated using target registration error (TRE), inverse consistency error (ICE) metrics, and a statistical image comparison using Gamma criteria of 1 % intensity difference in 2 mm(3) window range. Validation results showed that the proposed method was able to register CT lung datasets with TRE and ICE values <3 mm. In addition, the average number of voxel that failed the Gamma criteria was <3 %, which supports the clinical applicability of the propose registration mechanism. The proposed 4D-CT registration computes the volumetric lung deformations within clinically viable accuracy.

(PDF emailed within 0-6 h: $19.90)

Accession: 051047349

Download citation: RISBibTeXText

PMID: 24420697

DOI: 10.1007/s11548-013-0975-7



Related references

Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines. Medical Physics 31(11): 2942-2948, 2004

Landmark-based elastic registration using approximating thin-plate splines. IEEE Transactions on Medical Imaging 20(6): 526-534, 2001

A multi-resolution area-based technique for automatic multi-modal image registration. Image and Vision Computing 28(8): 1203-1219, 2010

Incorporation of landmark error ellipsoids for image registration based on approximating thin-plate splines. Lemke, H J, Vannier, M W, Inamura, K International Congress Series; CAR '97 Computer assisted radiology and surgery 234-239, 1997

Super-resolution reconstruction face recognition based on multi-level FFD registration. Optik - International Journal for Light and Electron Optics 124(24): 6926-6931, 2013

TPS-HAMMER: improving HAMMER registration algorithm by soft correspondence matching and thin-plate splines based deformation interpolation. Neuroimage 49(3): 2225-2233, 2010

Class modal analysis of a thin multi-trench-assisted liquid-filled optical waveguide coupler for simultaneous multi-sensing applications. Applied Optics 57(20): 5614-5622, 2018

Non-rigid surface registration using spherical thin-plate splines. Medical Image Computing and Computer-Assisted Intervention 10(Pt 1): 367-374, 2007

Interactive deformation registration of endorectal prostate MRI using ITK thin plate splines. Academic Radiology 16(3): 351-357, 2009

Multi-reverse flow injection analysis integrated with multi-optical sensor for simultaneous determination of Mn(II), Fe(II), Cu(II) and Fe(III) in natural waters. Talanta 166: 369-374, 2017

Impact of multi-resolution analysis of artificial intelligence models inputs on multi-step ahead river flow forecasting. Journal of Hydrology 507: 75-85, 2013

Landmarks thin plate splines and comparative anatomy of the primate scapula. American Zoologist 30(4): 73A, 1990

11 × 5 × 9.3Gb/s WDM-CAP-PON based on optical single-side band multi-level multi-band carrier-less amplitude and phase modulation with direct detection. Optics Express 21(16): 18842-8, 2013

Accurate crop-type classification using multi-temporal optical and multi-polarization SAR data in an object-based image analysis framework. International Journal of Remote Sensing 38(14): 4130-4155, 2017

Discriminative analysis of early Alzheimer's disease using multi-modal imaging and multi-level characterization with multi-classifier (M3). Neuroimage 59(3): 2187-2195, 2012