+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

A computerized scheme for lung nodule detection in multiprojection chest radiography



A computerized scheme for lung nodule detection in multiprojection chest radiography



Medical Physics 39(4): 2001-2012



Our previous study indicated that multiprojection chest radiography could significantly improve radiologists' performance for lung nodule detection in clinical practice. In this study, the authors further verify that multiprojection chest radiography can greatly improve the performance of a computer-aided diagnostic (CAD) scheme. Our database consisted of 59 subjects, including 43 subjects with 45 nodules and 16 subjects without nodules. The 45 nodules included 7 real and 38 simulated ones. The authors developed a conventional CAD scheme and a new fusion CAD scheme to detect lung nodules. The conventional CAD scheme consisted of four steps for (1) identification of initial nodule candidates inside lungs, (2) nodule candidate segmentation based on dynamic programming, (3) extraction of 33 features from nodule candidates, and (4) false positive reduction using a piecewise linear classifier. The conventional CAD scheme processed each of the three projection images of a subject independently and discarded the correlation information between the three images. The fusion CAD scheme included the four steps in the conventional CAD scheme and two additional steps for (5) registration of all candidates in the three images of a subject, and (6) integration of correlation information between the registered candidates in the three images. The integration step retained all candidates detected at least twice in the three images of a subject and removed those detected only once in the three images as false positives. A leave-one-subject-out testing method was used for evaluation of the performance levels of the two CAD schemes. At the sensitivities of 70%, 65%, and 60%, our conventional CAD scheme reported 14.7, 11.3, and 8.6 false positives per image, respectively, whereas our fusion CAD scheme reported 3.9, 1.9, and 1.2 false positives per image, and 5.5, 2.8, and 1.7 false positives per patient, respectively. The low performance of the conventional CAD scheme may be attributed to the high noise level in chest radiography, and the small size and low contrast of most nodules. This study indicated that the fusion of correlation information in multiprojection chest radiography can markedly improve the performance of CAD scheme for lung nodule detection.

(PDF emailed within 0-6 h: $19.90)

Accession: 051117135

Download citation: RISBibTeXText

PMID: 22482621

DOI: 10.1118/1.3694096


Related references

Development and evaluation of a computer-aided diagnostic scheme for lung nodule detection in chest radiographs by means of two-stage nodule enhancement with support vector classification. Medical Physics 38(4): 1844-1858, 2011

Lung nodule detection by means of GA and ANN approach in digital chest radiography. Lemke, H U, Vannier, M W, Inamura, K, Farman, A G International Congress Series; CAR '98: Computer assisted radiology and surgery 977, 1998

Lung nodule detection by microdose CT versus chest radiography (standard and dual-energy subtracted). Ajr. American Journal of Roentgenology 204(4): 727-735, 2015

Effect of multiscale processing in digital chest radiography on automated detection of lung nodule with a computer assistance system. Journal of Digital Imaging 21 Suppl 1: S164-S170, 2008

Usefulness of computerized method for lung nodule detection in digital chest radiographs using temporal subtraction images. Academic Radiology 18(8): 1000-1005, 2011

Computer-aided nodule detection on digital chest radiography: validation test on consecutive T1 cases of resectable lung cancer. Journal of Digital Imaging 19(4): 376-382, 2006

Usefulness of computerized method for lung nodule detection on digital chest radiographs using similar subtraction images from different patients. European Journal of Radiology 81(5): 1062-1067, 2012

Nodule detection in digital chest radiography: effect of nodule location. Radiation Protection Dosimetry 114(1-3): 92-96, 2005

Computer-aided diagnostic scheme for lung nodule detection in digital chest radiographs by use of a multiple-template matching technique. Medical Physics 28(10): 2070-2076, 2001

Quantitative assessment of the influence of anatomic noise on the detection of subtle lung nodule in digital chest radiography using fractal-feature distance. European Journal of Radiology 68(2): 353-357, 2007

Nodule detection in digital chest radiography: introduction to the RADIUS chest trial. Radiation Protection Dosimetry 114(1-3): 85-91, 2005

Nodule detection in digital chest radiography: summary of the RADIUS chest trial. Radiation Protection Dosimetry 114(1-3): 114-120, 2005

Pulmonary nodule detection of chest phantom with CRT images--comparison with conventional radiography (film-screen system) and FCR (Fuji Computed Radiography) hardcopy. Nihon Igaku Hoshasen Gakkai Zasshi. Nippon Acta Radiologica 49(8): 1038-1046, 1989

CsI-detector-based dual-exposure dual energy in chest radiography for lung nodule detection: results of an international multicenter trial. European Radiology 18(9): 1831-1839, 2008

Reduction of false positives in computerized detection of lung nodules in chest radiographs using artificial neural networks, discriminant analysis, and a rule-based scheme. Journal of Digital Imaging 7(4): 196-207, 1994