A glucose meter accuracy and precision comparison: the FreeStyle Flash Versus the Accu-Chek Advantage, Accu-Chek Compact Plus, Ascensia Contour, and the BD Logic



A glucose meter accuracy and precision comparison: the FreeStyle Flash Versus the Accu-Chek Advantage, Accu-Chek Compact Plus, Ascensia Contour, and the BD Logic



Diabetes Technology and Therapeutics 10(2): 102-110



This study compared the accuracy and precision of five blood glucose (BG) meters. Diabetes patients undergoing venipuncture for glucose testing were randomized to one of two groups consisting of three meters: FreeStyle Flash (Abbott Diabetes Care, Alameda, CA), Accu-Chek Advantage (Roche Diagnostics Corp., Indianapolis, IN), and Accu-Chek Compact Plus (Roche Diagnostics) or FreeStyle Flash, Ascensia Contour (Bayer Healthcare, Diagnostic Division, Tarrytown, NY), and BD Logic (BD Diabetes Care, Franklin Lake, NJ). Within 5 min following venipuncture, duplicate finger BG measurements from three ipsilateral fingers were taken. Finger glucose measurements were compared with laboratory reference values. Accuracy was assessed by a Clarke error grid analysis (EGA) and within 10% of the laboratory value criteria. Meter precision was determined by calculating the absolute mean differences in glucose values between duplicate samples. Finger sticks were obtained from 202 patients. Mean venipuncture BG was 148 mg/dL (SD +/- mg/64 dL; range 25-439 mg/dL). Accuracy by Clarke EGA (Zone A results) was demonstrated in 69% of Advantage samples, 75% of Compact Plus, and 96% of the first group of Flash versus 88% of the Contour, 67% of the Logic, and 91% of the second Flash samples (P < 0.05 for both Flash and Contour). Meter accuracy using the 10% criteria was demonstrated in 30%, 38%, 70%, 46%, 48%, and 68% of the samples, respectively (P < 0.05 for both Flash groups compared to each of the other meters). There were no differences in meter precision. No statistically significant differences in accuracy were evident using the Clarke EGA criteria (pooled results of Zone A and B), though the more strict 20% accuracy criteria (Zone A results only) found the Flash and Contour to have significantly greater accuracy compared to the Advantage, Compact Plus, and the Logic. Using the 10% accuracy criteria found the Flash to have significantly greater accuracy than each of the other four meters. All five meters demonstrated similar precision.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 051141708

Download citation: RISBibTeXText

PMID: 18260773

DOI: 10.1089/dia.2007.0244


Related references

Precision and accuracy of the Accu-Chek Advantage blood glucose monitoring system at high altitude. Clinical Chemistry 42(1): 115-117, 1996

A comparative evaluation of two sensor type blood glucose monitoring systems Accuracy and precision of the Accu-Chek Advantage-TM and Medisense Companion 2-TM. Clinical Chemistry 40(6): 1061, 1994

Evaluation of the accu chek bg blood glucose meter for accuracy. Clinical Chemistry 31(6): 1013, 1985

Monitoring neonatal hypoglycemia with the Accu-chek advantage II glucose meter: the cautionary tale of galactosemia. Clinical Chemistry 48(11): 2071, 2002

Comparison study of Accu-Chek Advantage and Precision QID meters with i-Stat as reference method using same finger tip capillary blood. Clinical Chemistry 45(6 PART 2): A33, 1999

Clinical evaluation of Accu-Chek EASY blood glucose meter. Clinical Chemistry 39(6): 1217, 1993

Evaluation of Accu-Chek Inform glucose meter in diabetic subjects. Clinical Chemistry 48(6 Suppl.): A193, 2002

An evaluation of the Accu-Chek Advantage blood glucose monitoring system. Clinical Chemistry 41(S6 PART 2): S192, 1995

Clinical evaluation of the Accu-Chek Sensor Module, a new glucose meter concept. Clinical Chemistry 48(6 Suppl.): A188, 2002

Capillary blood glucose screening (Accu-Chek Advantage) for gestational diabetes. Journal of the Medical Association of Thailand 92(10): 1268-1272, 2009

Clinical Evaluation of the Accu-Chek Advantage Blood Glucose Monitoring System. Laboratory Medicine 28(7): 462-466, 1997

An evaluation of the Accu-Chek Advantage GTS, Precision G, and Encore QA+ data management systems using venous and arterial blood. Clinical Chemistry 43(6 PART 2): S167, 1997

Evaluation of the integrated blood glucose monitoring system Accu-Chek Compact. Diabetes 50(Suppl. 2): A422, 2001

Investigation of Maltose Interference on the Roche ACCU-CHEK Inform II Blood Glucose Meter. Point of Care Journal of Near-Patient Testing & Technology 15(1): 26-29, 2016

Clinical and Analytical Performance of the Accu-Chek Inform Point-of-Care Glucose Meter. Point of Care Journal of Near-Patient Testing & Technology 4(1): 36-40, 2005