+ Recently Requested

A twelve-channel multiple-interferometer fabry-perot spectrometer



A twelve-channel multiple-interferometer fabry-perot spectrometer



Applied Optics 9(11): 2529-2534



A specialized spectrometer has been built to meet the time and spectral resolution requirements of a difficult plasma diagnosticexperiment. Two or three Fabry-Perot interferometers are arranged in series to provide the required spectral resolution and contrast.Twelve-channel output is produced by an annular mirror image dissector in the focal plane of the Fabry-Perot fringes. The spectralregion may be shifted by a change of gas pressure in the interferometer chambers. Measurements of the passband profiles with two interferometers are presented. Sample data from an experiment measuring the spectrum of ruby laser light after being scattered anddoppler broadened by a theta-pinch plasma are given.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 051280373

Download citation: RISBibTeXText

PMID: 20094300

DOI: 10.1364/AO.9.002529


Related references

Fourier transform spectrometer based on Fabry-Perot interferometer. Applied Optics 55(20): 5322-5331, 2016

The GREGOR Fabry-P erot Interferometer and its companion the Blue Imaging Solar Spectrometer. 2013

Compact imaging spectrometer combining Fourier transform spectroscopy with a Fabry-Perot interferometer. Optics Express 17(10): 8319-8331, 2009

Fourier transform two-dimensional fluorescence excitation spectrometer by using tandem Fabry-Pérot interferometer. Review of Scientific Instruments 86(1): 014101-014101, 2015

A simple terahertz spectrometer based on a low-reflectivity Fabry-Perot interferometer using Fourier transform spectroscopy. Optics Express 14(9): 3840-3846, 2006

Intensity transmitted by a Fabry-Perot etalon with another internal Fabry-Perot interferometer. Applied Optics 20(12): 2117-2120, 1981

A two-channel Fabry-Perot interferometer for the measurement of Doppler temperatures. Applied Optics 6(7): 1205-1207, 1967

Three-channel imaging fabry-perot interferometer for measurement of mid-latitude airglow. Applied Optics 40(24): 4286-4296, 2008

Lithium niobate double channel Fabry-Perot interferometer for solar corona uses. Applied Optics 27(24): 5095-5095, 1988

Design of a multiple-zone aperture and application to a Fabry-Perot interferometer. Applied Optics 19(10): 1622-1629, 1980

Multiple aperture exit plate for field-widening a Fabry-Perot interferometer. Applied Optics 24(2): 232-232, 1985

Multiple-fluorophore-specie detection with a tapered Fabry-Perot fluorescence spectrometer. Applied Optics 44(25): 5190-5197, 2005

Complex plane representation of a Fabry-Perot spectrometer output with multiple apertures. Applied Optics 25(4): 521-521, 1986

Wind-velocity lidar measurements by use of a Mach-Zehnder interferometer, comparison with a Fabry-Perot interferometer. Applied Optics 43(1): 173-182, 2004

Polar cap mesosphere wind observations: comparisons of simultaneous measurements with a Fabry-Perot interferometer and a field-widened Michelson interferometer. Applied Optics 39(24): 4284-4291, 2008