+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

A two-channel Fabry-Perot interferometer for the measurement of Doppler temperatures



A two-channel Fabry-Perot interferometer for the measurement of Doppler temperatures



Applied Optics 6(7): 1205-1207



The true width of a doppler-broadened emission line may easily be determined by measuring the peak and wing intensities of the fringe pattern. The ratio of these intensities as a function of the half-width of the line and of various instrumental parameters is discussed. This method has been used to study the ion temperature of a pulsed plasma.

(PDF emailed within 0-6 h: $19.90)

Accession: 051280545

Download citation: RISBibTeXText

PMID: 20062164

DOI: 10.1364/AO.6.001205


Related references

Three-channel imaging fabry-perot interferometer for measurement of mid-latitude airglow. Applied Optics 40(24): 4286-4296, 2008

Stratospheric temperature measurement with scanning Fabry-Perot interferometer for wind retrieval from mobile Rayleigh Doppler lidar. Optics Express 22(18): 21775-21789, 2014

Intensity transmitted by a Fabry-Perot etalon with another internal Fabry-Perot interferometer. Applied Optics 20(12): 2117-2120, 1981

Doppler line profile analysis for a multichannel Fabry-Perot interferometer. Applied Optics 23(4): 612-612, 1984

A twelve-channel multiple-interferometer fabry-perot spectrometer. Applied Optics 9(11): 2529-2534, 1970

Monostatic coaxial 1.5 μm laser Doppler velocimeter using a scanning Fabry-Perot interferometer. Optics Express 21(18): 21105-21112, 2013

Fabry-Perot interferometer based Mie Doppler lidar for low tropospheric wind observation. Applied Optics 46(29): 7120-7131, 2007

Nanometer measurement with a dual fabry-perot interferometer. Applied Optics 40(31): 5632-5637, 2008

A technique for recovering Doppler line profiles from fabry-perot interferometer fringes of very low intensity. Applied Optics 10(1): 193-200, 1971

Lithium niobate double channel Fabry-Perot interferometer for solar corona uses. Applied Optics 27(24): 5095-5095, 1988

Measurement of the group delay of laser mirrors by a Fabry-Perot interferometer. Optics Letters 20(22): 2339-2339, 1995

Simulation and analysis of a multi-order imaging Fabry-Perot interferometer for the study of thermospheric winds and temperatures. Applied Optics 50(22): 4403-4416, 2011

The Fabry Perot Interferometer as a primary calibration device in the measurement of earth strain. Special Paper - Geological Society of America Pages 448-449, 1968

Fabry-Pérot interferometer utilized for displacement measurement in a large measuring range. Review of Scientific Instruments 81(9): 093102-093102, 2010

Optical scanning extrinsic Fabry-Perot interferometer for absolute microdisplacement measurement. Applied Optics 36(34): 8858-8861, 2008