A study for determination of various positioning errors in digital panoramic radiography for evaluation of diagnostic image quality



A study for determination of various positioning errors in digital panoramic radiography for evaluation of diagnostic image quality



Indian Journal of Dental Research 28(6): 666-670



Faulty radiographs have poor diagnostic quality, and repetition of such poor-quality radiographs leads to increased patient exposure to radiation. Since digital panoramic radiography has replaced manual radiography, the only hindrance in producing good-quality radiographs is the positioning errors. Our study aims to determine the various positioning errors and their relative frequency and to identify those errors directly responsible for diagnostically inadequate images. Five hundred panoramic radiographs taken serially (from the year 2007) were retrospectively assessed for the positioning errors by three oral and maxillofacial radiology specialists using a performa enlisting the errors. The three specialists had different duration of clinical experience and they evaluated the orthopantograms as diagnostically acceptable or unacceptable. They also observed the relative frequency of all the positioning errors. The kappa value for intraobserver agreement was calculated, which suggested that the agreement among the observers was fair. Of the 500 panoramic radiographs viewed by the three observers, 25 (5%) had no errors, while 475 (95%) showed one or more positioning errors. The most common error in our study was found to be head turned to one side (33.8%) and the least common error was patient movement during exposure (1.8%). Positioning errors are very common in digital panoramic radiography, and they lead to production of poor-quality radiographs. The operator should take this fact into consideration and spend more time in patient positioning, thereby reducing the repetition of radiographs and unwanted patient exposure.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 051313648

Download citation: RISBibTeXText

PMID: 29256467


Related references

Evaluation of CRT-displayed and printout image quality in digital rotational panoramic radiography system Comparison between images obtained by the Orthophos DS CCD-based digital radiography system and analogue images on film. Shikwa Gakuho 100(9): 833-842, 2000

Positioning errors and quality assessment in panoramic radiography. Imaging Science in Dentistry 42(4): 207-212, 2012

Evaluation of CRT-displayed and printout image quality in digital rotational panoramic radiography system Comparison between images obtained by the Combi-X and Paxorama2000 computed radiography systems and analogue images on film, and effects of unsharp masking filter. Shikwa Gakuho 100(9): 843-857, 2000

The loss of image quality in digital panoramic radiography using image compression. Farman, A G, Ruprecht, A, Gibbs, S J, Scarfe, W C International Congress Series; IADMFR/CMI'97 Advances in maxillofacial imaging: 299-305, 1997

Series: Practical Evaluation of Clinical Image Quality (4): Determination of Image Quality in Digital Radiography System. Igaku Butsuri 36(3): 166-172, 2017

The subjective image quality of direct digital and conventional panoramic radiography. Clinical Oral Investigations 4(3): 162-167, 2000

The comparison of subjective image quality in conventional and digital panoramic radiography. Indian Journal of Dental Research 20(1): 21-25, 2009

Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss. Contemporary Clinical Dentistry 5(3): 318-323, 2014

The subjective image quality of conventional and digital panoramic radiography among 6 to 10 year old children. Journal of Clinical Pediatric Dentistry 31(2): 109-112, 2006

Image quality assessment in panoramic dental radiography: a comparative study between conventional and digital systems. Quantitative Imaging in Medicine and Surgery 3(1): 43-48, 2013

Common positioning and technical errors in panoramic radiography. Journal of the American Dental Association 113(3): 422-426, 1986

Common positioning errors in panoramic radiography: A review. Imaging Science in Dentistry 44(1): 1-6, 2014

Series: Practical Evaluation of Clinical Image Quality (3): Subjective Evaluation of Image Quality in Digital Radiography Systems. Igaku Butsuri 36(2): 113-120, 2017

Clinical image quality evaluation for panoramic radiography in Korean dental clinics. Imaging Science in Dentistry 42(3): 183-190, 2012

A comparison of panoramic image quality between a digital radiography storage phosphor system and a film-based system. Journal of Contemporary Dental Practice 11(1): E009, 2010