Accelerated algorithm of dose calculation for treatment planning system of multi-source stereotactic radiotherapy system with gamma beam



Accelerated algorithm of dose calculation for treatment planning system of multi-source stereotactic radiotherapy system with gamma beam



Zhongguo Yi Liao Qi Xie Za Zhi 36(1): 15-18



This paper reviewed the dose calculation method for treatment planning system of multi-source stereotactic radiotherapy system with Gamma beam, and presented a fast method based on cone coordinate system and multi-core parallelization. The experiments show that the new method not only ensures the accuracy of dose calculation, but also greatly improves the speed, which can reach as 20 times as that of traditional method.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 051319315

Download citation: RISBibTeXText

PMID: 22571144


Related references

SU-E-T-537: Photon Beam Modeling and Verification of Collapsed Cone Convolution Algorithm for Dose Calculation in a Radiation Treatment Planning System. Medical Physics 39(6part18): 3829, 2012

Source modeling for Monte Carlo dose calculation of CT examinations with a radiotherapy treatment planning system. Medical Physics 43(11): 6118, 2016

Monte Carlo calculation of single-beam dose profiles used in a gamma knife treatment planning system. Medical Physics 25(9): 1673-1675, 1998

Dose calculation models for proton treatment planning using a dynamic beam delivery system: an attempt to include density heterogeneity effects in the analytical dose calculation. Physics in Medicine and Biology 44(1): 27-41, 1999

A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm. International Journal of Radiation Oncology, Biology, Physics 63(2): 622-633, 2005

Dose accuracy check of the 3D electron beam algorithm in a treatment planning system. Physics in Medicine and Biology 43(6): 1529-1544, 1998

Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size. Radiation Oncology 10: 53, 2016

Effect of computed tomography number-relative electron density conversion curve on the calculation of radiotherapy dose and evaluation of Monaco radiotherapy treatment planning system. Australasian Physical and Engineering Sciences in Medicine 2019, 2019

Advantages of multiple algorithm support in treatment planning system for external beam dose calculations. Journal of Cancer Research and Therapeutics 1(1): 12-20, 2007

Influence on dose calculation by difference of dose calculation algorithms in stereotactic lung irradiation: comparison of pencil beam convolution (inhomogeneity correction: batho power law) and analytical anisotropic algorithm. Nihon Hoshasen Gijutsu Gakkai Zasshi 65(8): 1064-1072, 2009

1559 poster Migration Of Dose Calculation Algorithm From Pbc To Aaa For Stereotactic Lung Cancer Treatment Planning. Radiotherapy and Oncology 99: S580-S581, 2011

Comparison of two dose calculation methods applied to extracranial stereotactic radiotherapy treatment planning. RadioTherapy and Oncology 77(1): 96-98, 2005

Experimental evaluation of a GPU-based Monte Carlo dose calculation algorithm in the Monaco treatment planning system. Journal of Applied Clinical Medical Physics 17(6): 230-241, 2017

Effect of low-density heterogeneities in telecobalt therapy and validation of dose calculation algorithm of a treatment planning system. Journal of Medical Physics 36(4): 198-204, 2012

Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM. Medical Physics 27(7): 1579-1587, 2000