+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Acoustic radiation force impulse imaging with Virtual Touch™ tissue quantification: mean shear wave velocity of malignant and benign breast masses



Acoustic radiation force impulse imaging with Virtual Touch™ tissue quantification: mean shear wave velocity of malignant and benign breast masses



International Journal of Women's Health 5: 619-627



Acoustic radiation force impulse imaging (ARFI) with Virtual Touch™ tissue quantification (VTTQ) enables the determination of shear wave velocity (SWV) in meters per second (m/s). The aim of our study was to describe the mean SWV in normal breast tissue and various breast masses. We performed measurements of SWV with ARFI VTTQ in 145 breast masses (57 malignant, 88 benign) and in the adjacent breast parenchyma and adipose tissue. The mean SWV as well as the rate of successful measurements were analyzed. The difference between adipose tissue and parenchyma was statistically significant (3.05 versus 3.65 m/s) (P < 0.001). Focusing on breast masses, numerous measurements exceeded the upper limit of possible measurement (≥9.10 m/s, indicated as "X.XX m/s"). Nevertheless, the difference between the malignant and benign masses was statistically significant (8.38 ± 1.99 m/s versus 5.39 ± 2.95 m/s) (P < 0.001). The best diagnostic accuracy (75.9%) was achieved when the cutoff point for malignancy was set to 9.10 m/s in ARFI VTTQ. This implies that the SWV was regarded as suspicious when the upper limit of possible measurement was exceeded and the machine returned the value X.XX m/s. In conclusion, ARFI VTTQ is a feasible method for measurement of SWV in a region of interest. Furthermore, we propose the event of a highly elevated SWV as a significant criterion for malignancy. However, the method is technically not yet fully developed, and the problem of unsuccessful measurements must still be solved.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 051335529

Download citation: RISBibTeXText

PMID: 24109199

DOI: 10.2147/ijwh.s50953


Related references

Virtual touch tissue quantification using acoustic radiation force impulse technology: initial clinical experience with solid breast masses. Journal of Ultrasound in Medicine 31(2): 289-294, 2012

Differentiation of benign and malignant focal liver lesions: value of virtual touch tissue quantification of acoustic radiation force impulse elastography. Medical Oncology 32(3): 68, 2015

Acoustic radiation force impulse imaging with virtual touch tissue quantification: measurements of normal breast tissue and dependence on the degree of pre-compression. Ultrasound in Medicine and Biology 39(12): 2226-2232, 2013

Virtual touch tissue imaging on acoustic radiation force impulse elastography: a new technique for differential diagnosis between benign and malignant thyroid nodules. Journal of Ultrasound in Medicine 33(4): 585-595, 2014

Reliable measurement procedure of virtual touch tissue quantification with acoustic radiation force impulse imaging. Journal of Ultrasound in Medicine 30(6): 745-751, 2011

Shear wave velocity measurements for differential diagnosis of solid breast masses: a comparison between virtual touch quantification and virtual touch IQ. Ultrasound in Medicine and Biology 39(12): 2233-2245, 2013

Reliable measurement by virtual touch tissue quantification with acoustic radiation force impulse imaging: phantom study. Journal of Ultrasound in Medicine 31(8): 1239-1244, 2012

Virtual touch tissue quantification of acoustic radiation force impulse: a new ultrasound elastic imaging in the diagnosis of thyroid nodules. Plos one 7(11): E49094, 2012

Reliability analysis of acoustic radiation force impulse ultrasound imaging with virtual touch tissue quantification: ex vivo ox liver. Ultrasound Quarterly 31(1): 59-62, 2015

Acoustic radiation force impulse (ARFI) imaging with Virtual Touch Tissue Quantification in liver disease associated with cystic fibrosis in children. La Radiologia Medica 117(8): 1408-1418, 2012

Evaluation of virtual touch tissue imaging quantification, a new shear wave velocity imaging method, for breast lesion assessment by ultrasound. Biomed Research International 2014: 960262, 2014

Acoustic Radiation Force Impulse Imaging With Virtual Touch Tissue Quantification Enables Characterization of Mild Hypoxic-Ischemic Brain Damage in Neonatal Rats. Journal of Ultrasound in Medicine 38(7): 1797-1805, 2019

Quantitative Shear Wave Velocity Measurement on Acoustic Radiation Force Impulse Elastography for Differential Diagnosis between Benign and Malignant Thyroid Nodules: A Meta-analysis. Ultrasound in Medicine and Biology 41(12): 3035-3043, 2015

Acoustic radiation force impulse with shear wave speed quantification of pancreatic masses: A prospective study. Pancreatology 16(1): 106-109, 2016

Virtual touch tissue imaging quantification shear wave elastography for determining benign versus malignant cervical lymph nodes: a comparison with conventional ultrasound. Diagnostic and Interventional Radiology 25(2): 114-121, 2019