+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Analysis of von Willebrand factor multimers by simultaneous high- and low-resolution vertical SDS-agarose gel electrophoresis and Cy5-labeled antibody high-sensitivity fluorescence detection



Analysis of von Willebrand factor multimers by simultaneous high- and low-resolution vertical SDS-agarose gel electrophoresis and Cy5-labeled antibody high-sensitivity fluorescence detection



American Journal of Clinical Pathology 133(2): 322-330



Analysis of von Willebrand factor (vWF) multimers allows classification of the subtypes of von Willebrand disease (vWD) in human serum and platelet lysates. A novel method for multimer analysis of vWF by 2-chamber, vertical (sodium dodecyl sulfate), agarose gel electrophoresis, designed for comparing discontinuous high- and low-resolving gels for plasma and platelets, followed by Western blotting and high-sensitivity fluorescence detection (HSFD) of cyanine (Cy)5-labeled vWF multimers is presented. HSFD shows that this method has high discriminatory power for visualization and densitometric analysis of platelets and plasma vWF multimers in various types of vWD and allows rapid classification of vWD types, to separate types 2A and 2B. The described procedures of vWF multimer analysis with high-sensitivity Cy5 fluorescence detection and direct comparison of high- and low-resolving gels for screening and detection of the complete range of high- and low-molecular vWF multimers is efficient and useful for screening, detecting, and classifying vWD subtypes and makes this method diagnostically and clinically relevant.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 051533127

Download citation: RISBibTeXText

PMID: 20093243

DOI: 10.1309/ajcpzsbtd2bwomvl


Related references

A rapid method to visualize von Willebrand Factor multimers by using agarose gel electrophoresis, immunolocalization and luminographic detection. Thrombosis Research 97(6): 457-462, 2000

An optimized electrophoresis method for high-resolution imaging of von-Willebrand multimers. Thrombosis and Haemostasis 100(5): 949-951, 2008

High-resolution analysis of von Willebrand factor multimeric composition defines a new variant of type I von Willebrand disease with aberrant structure but presence of all size multimers (type IC). Blood 66(6): 1423-1429, 1985

Electroblotting of factor VIII/von Willebrand factor multimers after electrophoresis in SDS-agarose gel, discontinuous buffer system. British Journal of Haematology 55(1): 195-196, 1983

Influence of different surfactants on the separation of von Willebrand factor multimers by use of agarose gel electrophoresis and semi dry blotting technology. Thrombosis Research 61(3): 181-189, 1991

Clinical applications of high resolution two dimensional electrophoresis 2de of proteins comparative analysis by 2de of proteins in high resolution agarose electrophoresis hre bands and current medical indications for 2 de analysis of serum proteins. Clinical Chemistry 35(6): 1083, 1989

Luminographic detection of von Willebrand factor multimers in agarose gels and on nitrocellulose membranes. Thrombosis and Haemostasis 63(2): 312-315, 1990

High sensitivity analysis of water-soluble, cyanine dye labeled proteins by high-performance liquid chromatography with fluorescence detection. Analytica Chimica Acta 640(1-2): 114-120, 2009

Update on von Willebrand factor multimers: focus on high-molecular-weight multimers and their role in hemostasis. Blood Coagulation and Fibrinolysis 25(3): 206-216, 2014

High-resolution imaging of multimers can detect von Willebrand's disease type 2A even if ristocetin cofactor is higher than von Willebrand antigen. Haemophilia 17(2): 325-326, 2011

Dependence of von Willebrand Factor Activity in Relation to the High-Molecular-Weight von Willebrand Factor Multimers in Various VWF/FVIII-Concentrates. Blood 100(11): Abstract No 3883, 2002

High-sensitivity analysis of cyanide by capillary electrophoresis with fluorescence detection. Analytical Sciences 17(5): 649-652, 2001

A very-high-purity von Willebrand factor preparation containing high-molecular-weight multimers. Vox Sanguinis 76(2): 85-89, 1999

High resolution multichannel fluorescence detection for capillary electrophoresis: Application to multicomponent analysis. Journal of Chromatography A 788(1-2): 173-183, 1997

High resolution multichannel fluorescence detection for capillary electrophoresis. Application to multicomponent analysis. Journal of Chromatography. a 788(1-2): 173-183, 1997