+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Application of a glass rod detector for the output factor measurement in the CyberKnife



Application of a glass rod detector for the output factor measurement in the CyberKnife



Applied Radiation and Isotopes 66(12): 1980-1985



A radiophotoluminescent glass rod detector has recently become commercially available. We evaluated the feasibility of the commercial glass rod as a new detector for measuring output factors in the CyberKnife. The glass rod detector was irradiated in a water phantom using a holder stand, which was specially designed for this study. The holder was composed of a PMMA tube with an attached vertical bar for the glass rod detector. The measured output factors obtained with the glass rod detector were compared with measurements made with a pinpoint ionization chamber, a diode, and a radiochromic film. The measured relative output factors obtained with the glass rod detector agreed with other detectors within 1.0% for collimator sizes larger than 20mm. However, it was observed that the differences between the output factors measured with the glass rod detector and those obtained with the pinpoint chamber increased rapidly as the collimator size decreased. The relative output factors measured with the diode were consistently higher than those obtained using other detectors for the collimators sizes less than 10mm in diameter. The glass rod detector results were in good agreement with those obtained from the radiochromic EBT film over the entire range of collimator sizes.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 051607270

Download citation: RISBibTeXText

PMID: 18693026

DOI: 10.1016/j.apradiso.2008.06.041


Related references

Monte Carlo simulated correction factors for output factor measurement with the CyberKnife system-results for new detectors and correction factor dependence on measurement distance and detector orientation. Physics in Medicine and Biology 59(6): N11-N17, 2014

The use of a radiophotoluminescent glass rod detector for the determination of cyberknife stereotactic radiosurgery system output factors. 2007

Poster The use of a radiophotoluminescent glass rod detector for the determination of cyberknife stereotactic radiosurgery system output factors. European Journal of Cancer Suppl.s 5(4): 327-328, 2007

Sci-Thur AM: Planning - 10: Improved dosimetric accuracy for patient specific quality assurance using a dual-detector measurement method for cyberknife output factors. Medical Physics 39(7part2): 4621, 2012

CyberKnife beam output factor measurements: A multi-site and multi-detector study. Physica Medica 32(12): 1637-1643, 2016

PO-0839: Synthetic diamond detector for CyberKnife beam output measurements: a multi-site study. RadioTherapy and Oncology 115: S424-S425, 2015

Monte Carlo simulated correction factors for machine specific reference field dose calibration and output factor measurement using fixed and iris collimators on the CyberKnife system. Physics in Medicine and Biology 57(12): 3741-3758, 2012

Multicenter evaluation of a synthetic single-crystal diamond detector for CyberKnife small field size output factors. Physica Medica 32(4): 575-581, 2016

Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams. Physics in Medicine & Biology 47(20): 3643-3649, 21 October, 2002

Efficiency measurement in the hotel industry: output factor constrained DEA application. Anatolia 11(2): 111-123, 2000

Sci-Fri PM: Delivery - 07: Cyberknife relative output factor measurements using fiber-coupled luminescence, MOSFETS and RADPOS dosimetry system. Medical Physics 39(7part4): 4643, 2012

Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector. Nihon Hoshasen Gijutsu Gakkai Zasshi 60(1): 67-68, 2004

Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector. Medical Physics 30(8): 1976-1981, 2003

Volumetric measurement pulmonary ground-glass opacity nodules with multi-detector CT: effect of various tube current on measurement accuracy--a chest CT phantom study. Academic Radiology 16(8): 934-939, 2009

Detector to detector corrections: a comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams. Medical Physics 41(7): 072103, 2014