+ Site Statistics
References:
52,654,530
Abstracts:
29,560,856
PMIDs:
28,072,755
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn

+ Translate
+ Recently Requested

Application of a navigation system for contouring anatomical plasty of the distal end of the humerus



Application of a navigation system for contouring anatomical plasty of the distal end of the humerus



Computer Aided Surgery 17(4): 179-186



The effectiveness of navigation systems in performing accurate orthopaedic surgery has been reported previously, but there have been no reports on the application of navigation in surgeries involving bone resection around the elbow joint. In this study, anatomical plasty or bone resection was performed to restore anatomical morphology in 10 cases of osteoarthritis of the elbow and deformity of the distal end of the humerus. Bone resection was performed on the distal end of the humerus using navigation and on the proximal end of the ulna via freehand surgery. Postoperatively, the elbow function was evaluated and pre- and postoperative CT images were used to measure the bone resection. There were no complications arising from the use of navigation, and elbow function was improved in all cases. By evaluating the CT images, it was found that navigated resection of the fossae of the distal humerus was more effective than freehand resection of the processes of the proximal ulna, thus confirming the usefulness of navigation. In future, to fully confirm this finding, it will be necessary to conduct prospective controlled studies of cases in which navigation is used to perform arthroplasty, including those that involve the proximal end of the ulna.

(PDF emailed within 0-6 h: $19.90)

Accession: 051607434

Download citation: RISBibTeXText

PMID: 22681497

DOI: 10.3109/10929088.2012.692815



Related references

Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: preliminary results with the LCP distal humerus system. Archives of Orthopaedic and Trauma Surgery 128(7): 723-729, 2007

Treatment for type C fractures of the distal humerus with the LCP distal humerus system. European Journal of Orthopaedic Surgery & Traumatology 22(7): 565-569, 2012

Parallel Plating of Simulated Distal Humerus Fractures Demonstrates Increased Stiffness Relative to Orthogonal Plating With a Distal Humerus Locking Plate System. Journal of Orthopaedic Trauma 30(4): E118-E122, 2015

Treatment of supra- and intra-articular fractures of the distal humerus with the LCP Distal Humerus Plate: a 2-year follow-up. Journal of Shoulder and Elbow Surgery 20(2): 206-212, 2011

Computer-assisted auto-frame navigation system for distal locking of tibial intramedullary nails: a preliminary report on clinical application. Chinese Journal of Traumatology 9(3): 138-145, 2006

Anatomical plate configuration affects mechanical performance in distal humerus fractures. Clinical Biomechanics 25(10): 972-978, 2011

Anatomical basis of the risk of radial nerve injury related to the technique of external fixation applied to the distal humerus. Surgical and Radiologic Anatomy 32(3): 221-224, 2010

Cement-plasty of distal radius using a calcium phosphate bone cement : anatomical experimental study in 20 wrists. Archives of Physiology and Biochemistry 111(Suppl. S): 65, 2003

Distal fractures of the canine humerus. Application of the classification of Unger et al. (1990). Kleintierpraxis 36(8): 411...422, 1991

Minimally invasive application of the non-contact-bridging (NCB) plate to the proximal humerus: an anatomical study. Journal of Orthopaedic Trauma 21(9): 621-627, 2007

Computer assisted orthopaedic surgical system for insertion of distal locking screws in intra-medullary nails: a valid and reliable navigation system. International Journal of Medical Robotics + Computer Assisted Surgery 1(4): 34-44, 2007

A comprehensive classification system for intercondylar fractures of the distal humerus. Contemporary Orthopaedics 25(4): 343-351, 1992

Accuracy of an image-free cup navigation system--an anatomical study. Biomedizinische Technik. Biomedical Engineering 49(9): 257-262, 2004

A biplanar robot navigation system for the distal locking of intramedullary nails. International Journal of Medical Robotics + Computer Assisted Surgery 6(1): 61-65, 2010

Double-locking precontoured plating system for malunited fractures of the distal end of humerus. Musculoskeletal Surgery 100(Suppl 1): 105-110, 2016