Application of a wireless resonance frequency transducer to assess primary stability of orthodontic mini-implants: an in vitro study in pig ilia



Application of a wireless resonance frequency transducer to assess primary stability of orthodontic mini-implants: an in vitro study in pig ilia



International Journal of Oral and Maxillofacial Implants 24(4): 647-654



The aim of the study was to evaluate whether resonance frequency analysis (RFA) using a wireless transducer can be used to assess the primary stability of orthodontic mini-implants. Fifteen orthodontic mini-implants were placed in three ilium bone segments of country pigs. The wireless resonance frequency transducer was bonded to the head of the mini-implants, and RFA values of the mini-implants in bone were detected and converted into implant stability quotient (ISQ) values by the RFA monitor. In addition, the percussion test value, peri-implant radiographic bone density, and cortical bone thickness were measured. The ISQ values of mini-implants correlated linearly with peri-implant radiographic bone density (r = 0.92, P < .0001), cortical bone thickness (r = 0.90, P < .0001), and percussion test values (r = -0.91, P < .0001), respectively. In addition, by means of the calculation of 99% confidence intervals, the absolute values of the three correlation coefficients ranged from 0.61 to 0.98. This in vitro animal study showed that the presented RFA method using a wireless transducer might have potential to provide an alternative noninvasive assessment of the primary stability of an orthodontic mini-implant.

(PDF emailed within 1 workday: $29.90)

Accession: 051607821

Download citation: RISBibTeXText

PMID: 19885404



Related references

An in vitro study of factors affecting the primary stability of orthodontic mini-implants. Angle Orthodontist 82(6): 1022-1028, 2013

A clinical evaluation on the stability of orthodontic mini-implants using resonance frequency analysis. Shanghai Kou Qiang Yi Xue 23(5): 614-618, 2015

An evaluation of resonance frequency analysis for the determination of the primary stability of orthodontic palatal implants. A study in human cadavers. Clinical Oral Implants Research 16(4): 425-431, 2005

A torque removal study on the primary stability of orthodontic titanium screw mini-implants in the cortical bone of dog femurs. International Journal of Oral and Maxillofacial Surgery 37(7): 647-650, 2008

Assessment of stability of orthodontic mini-implants under orthodontic loading: A computed tomography study. Indian Journal of Dental Research 26(3): 237-243, 2017

Parameters affecting primary stability of orthodontic mini-implants. Journal of Orofacial Orthopedics 67(3): 162-174, 2006

Evaluation of primary stability of inclined orthodontic mini-implants. Journal of Oral Science 51(3): 347-353, 2010

In vitro and in vivo mechanical stability of orthodontic mini-implants. Angle Orthodontist 82(4): 611-617, 2013

Influence of different implant materials on the primary stability of orthodontic mini-implants. Kaohsiung Journal of Medical Sciences 28(12): 673-678, 2013

Insertion angle impact on primary stability of orthodontic mini-implants. Angle Orthodontist 78(6): 1065-1070, 2008

Impact of implant design on primary stability of orthodontic mini-implants. Journal of Orofacial Orthopedics 69(1): 42-50, 2008

Primary stability of orthodontic mini-implants inserted into maxilla and mandible of swine. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology 113(6): 748-754, 2013

Impact of insertion depth and predrilling diameter on primary stability of orthodontic mini-implants. Angle Orthodontist 79(4): 609-614, 2009

Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants. Journal of Oral Rehabilitation 36(10): 755-761, 2010

Machine-driven versus manual insertion mode: influence on primary stability of orthodontic mini-implants. Implant Dentistry 24(1): 31-36, 2016