+ Site Statistics
References:
52,654,530
Abstracts:
29,560,856
PMIDs:
28,072,755
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn

+ Translate
+ Recently Requested

Application of algebraic iterative reconstruction in imaging reconstruction of SPECT



Application of algebraic iterative reconstruction in imaging reconstruction of SPECT



Zhongguo Yi Liao Qi Xie Za Zhi 34(1): 21-23



By comparing routine FBP with algebraic iterative reconstruction, this study exploit the effect of the two SPECT reconstruction techniques on the ratio of Target/Background (T/B) and image noise. The result of research on model and clinical cases showed that the technique of OSEM could increase T/B ratio by 1.5% (heart), 3.3% (bone), 1.4% (brain). No obvious difference in image noise existed between OSEM and FBP. Compared with FBP, OSEM could improve T/B value in bone focus more significantly. Under the same injection dosage, OSEM could increase the speed of image collection by more than one time without changes in image quality and T/B ratio. The result suggested that function and clinical application of SPECT would significantly improved by substituting routine FBP with OSEM.

(PDF emailed within 1 workday: $29.90)

Accession: 051607959

Download citation: RISBibTeXText

PMID: 20391922



Related references

Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR). European Radiology 25(1): 140-146, 2015

Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine. Magnetic Resonance in Medicine 73(4): 1643-1653, 2015

AB-EMML Iterative reconstruction algorithm incorporating upper and lower bounds with application to SPECT transmission imaging. Journal of Nuclear Medicine 39(5 SUPPL ): 180P, 1998

Computed Tomography Image Quality Evaluation of a New Iterative Reconstruction Algorithm in the Abdomen (Adaptive Statistical Iterative Reconstruction-V) a Comparison With Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection Reconstructions. Journal of Computer Assisted Tomography, 2017

An interior point iterative maximum-likelihood reconstruction algorithm incorporating upper and lower bounds with application to SPECT transmission imaging. IEEE Transactions on Medical Imaging 20(4): 342-353, 2001

Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction. European Radiology 24(4): 799-806, 2014

Evaluation of iterative reconstruction methods for use in spect imaging. Journal of Nuclear Medicine 32(5 SUPPL): 937, 1991

Pinhole SPECT imaging: compact projection/backprojection operator for efficient algebraic reconstruction. IEEE Transactions on Medical Imaging 25(2): 158-167, 2006

9. Clinical application 7: iterative reconstruction algorithm of SPECT and PET. Nihon Hoshasen Gijutsu Gakkai Zasshi 71(1): 66-71, 2015

Fast iterative reconstruction for helical pinhole SPECT imaging. Bio-Medical Materials and Engineering 26 Suppl 1: S1371-S1380, 2016

Variable scale reconstruction with non-uniform attenuation for SPECT iterative reconstruction. Journal of Nuclear Medicine 42(5 Supplement): 57P-58P, 2001

Upgrade to iterative image reconstruction (IR) in abdominal MDCT imaging: a clinical study for detailed parameter optimization beyond vendor recommendations using the adaptive statistical iterative reconstruction environment (ASIR). Rofo 184(3): 229-238, 2012

Determination of optimal imaging settings for urolithiasis CT using filtered back projection (FBP), statistical iterative reconstruction (IR) and knowledge-based iterative model reconstruction (IMR): a physical human phantom study. British Journal of Radiology 89(1058): 20150527-20150527, 2016

Upgrade to iterative image reconstruction (IR) in MDCT imaging: a clinical study for detailed parameter optimization beyond vendor recommendations using the adaptive statistical iterative reconstruction environment (ASIR) Part2: The chest. Rofo 185(7): 644-654, 2013

Application of stopping criteria for iterative maximum likelihood em reconstruction in spect. Journal of Nuclear Medicine 30(5 SUPPL): 882, 1989