Assessment of image quality on effects of varying tube voltage and automatic tube current modulation with hybrid and pure iterative reconstruction techniques in abdominal/pelvic CT: a phantom study



Assessment of image quality on effects of varying tube voltage and automatic tube current modulation with hybrid and pure iterative reconstruction techniques in abdominal/pelvic CT: a phantom study



Investigative Radiology 48(3): 167-174



The objective of this study was to compare image quality on abdominal/pelvic computed tomographic images acquired with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and novel model-based iterative reconstruction (MBIR) techniques with varying levels of automatic tube current modulation and tube voltages. A 2-phase study was performed. In phase 1, a torso phantom was scanned at 17 different noise levels of automatic current modulation (selected using noise index [NI]) at 120 kilovolt (peak) (kVp). Images reconstructed with FBP, ASIR, and MBIR underwent objective analysis. In phase 2, additional scans were performed at 3 different kVp (80, 100, and 120 kVp at 3 different NIs (33, 50, and 70). Objective and subjective image qualities were assessed. Computed tomography dose index and dose-length products were recorded. The objective image analysis supports significant noise reduction with MBIR compared with ASIR and FBP (P < 0.05) at all 17 NI tested at 120 kVp. When lowering the kVp, the subjective image quality was improved, but when this is performed in conjunction with increasing NI, image quality was maintained only at moderately high NI of 50 but was degraded at higher NIs despite improving contrast-to-noise ratio. Our results represent the first exploration in the utility of MBIR technique with alteration of kVp in conjunction with tube current modulation in comparison with traditional methods. Objective image noise for MBIR is superior. Subjective image quality is only moderately improved. Scanning at low kVp and moderately high NI with MBIR can ensure that a balance of improved image noise and contrast can be achieved as well as reducing dose.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 051661860

Download citation: RISBibTeXText

PMID: 23344519

DOI: 10.1097/rli.0b013e31827b8f61


Related references

Image Quality Assessment in Torso Phantom Comparing Effects of Varying Automatic Current Modulation with Filtered Back Projection, Adaptive Statistical, and Model-Based Iterative Reconstruction Techniques in CT. Journal of Medical Imaging and Radiation Sciences 43(4): 228-238, 2012

Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study. Academic Radiology 16(8): 997, 2009

Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality. Investigative Radiology 54(5): 265-272, 2019

Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality. Korean Journal of Radiology 16(3): 531-540, 2015

Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience. Radiology 254(1): 145-153, 2010

Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study. Radiology 260(2): 454-462, 2011

Dose and Image Quality in Low-dose CT for Urinary Stone Disease: Added Value of Automatic Tube Current Modulation and Iterative Reconstruction Techniques. Radiation Protection Dosimetry 174(2): 242-249, 2017

The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study. Journal of X-Ray Science and Technology 21(4): 453-464, 2013

Ultra-low dose CT colonography with automatic tube current modulation and sinogram-affirmed iterative reconstruction: Effects on radiation exposure and image quality. Journal of Applied Clinical Medical Physics 20(1): 321-330, 2019

Low-dose abdominal CT: comparison of low tube voltage with moderate-level iterative reconstruction and standard tube voltage, low tube current with high-level iterative reconstruction. Clinical Radiology 68(10): 1008-1015, 2013

Low-dose CT with automatic tube current modulation, adaptive statistical iterative reconstruction, and low tube voltage for the diagnosis of renal colic: impact of body mass index. Ajr. American Journal of Roentgenology 202(3): 553-560, 2014

Improvement of image quality at low-radiation dose and low-contrast material dose abdominal CT in patients with cirrhosis: intraindividual comparison of low tube voltage with iterative reconstruction algorithm and standard tube voltage. Journal of Computer Assisted Tomography 36(4): 495-501, 2012

Performance of adaptive iterative dose reduction 3D integrated with automatic tube current modulation in radiation dose and image noise reduction compared with filtered-back projection for 80-kVp abdominal CT: Anthropomorphic phantom and patient study. European Journal of Radiology 85(9): 1666-1672, 2016

Do metallic endoprostheses increase radiation dose associated with automatic tube-current modulation in abdominal-pelvic MDCT? A phantom and patient study. Ajr. American Journal of Roentgenology 184(2): 491-496, 2005

Effect of automatic tube voltage selection on image quality and radiation dose in abdominal CT angiography of various body sizes: a phantom study. Clinical Radiology 68(2): E79-E86, 2013