+ Site Statistics
References:
52,654,530
Abstracts:
29,560,856
PMIDs:
28,072,755
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn

+ Translate
+ Recently Requested

Assessment of ion imprinted polymers based on Pd(II) chelate complexes for preconcentration and FAAS determination of palladium



Assessment of ion imprinted polymers based on Pd(II) chelate complexes for preconcentration and FAAS determination of palladium



Talanta 83(2): 596-604



New ion-imprinted polymeric (IIP) materials were synthesized by copolymerization of 4-vinylpyridine (VP) and styrene as functional monomers and divinylbenzene as a cross-linking agent with chelating complexes of Pd(II) in the presence of 2,2-azobisisobutyronitrile as an initiator. The complexes of Pd(II) with ammonium pyrrolidinedithiocarbamate (APDC), N,N'-diethylthiourea (DET), and dimethylglyoxime (DMG) were used for this purpose. Chloroform, ethanol, and cyclohexanol were applied as porogens. The ion-imprinted polymers were tested in a flow mode as sorbents for solid-phase extraction of palladium from aqueous solutions. The conditions of Pd(II) separation on all polymers were optimized. The efficiencies of retention of Pd on different polymers in the presence of high excess of interfering ions were compared. The effect of the used porogen on the analytical performance of the prepared polymers was also investigated. The calculated sorbent capacities for Pd(II) were in the range from 9.25 mg g(-1) to 13.3 mg g(-1). The sorbent with Pd(II) imprinted as Pd-DMG-VP complex in chloroform was used for preconcentration of trace amounts of Pd. The detection limit for 100mL of the sample was 5 μg L(-1) using flame atomic absorption spectrometry (FAAS). The developed method was applied for the determination of Pd in water samples.

(PDF emailed within 0-6 h: $19.90)

Accession: 051662249

Download citation: RISBibTeXText

PMID: 21111180

DOI: 10.1016/j.talanta.2010.10.005


Related references

Application of a metal ion-imprinted polymer based on salen-Cu complex to flow injection preconcentration and FAAS determination of copper. Talanta 76(1): 96-101, 2008

FAAS determination of gold and palladium using an on-line separation and preconcentration system based on a high-selective chelating adsorbent. Atomic Spectroscopy 22(5): 392-397, 2001

Cloud point extraction for the preconcentration of palladium and lead in environmental samples and determination by flow injection flame atomic absorption spectrometry: CPE for preconcentration of Pd and Pb by FI-FAAS. Environmental Science and Pollution Research International 19(6): 2428-2437, 2012

Preparation of dendrimer-like polyamidoamine immobilized silica gel and its application to online preconcentration and separation palladium prior to FAAS determination. Talanta 62(5): 918-923, 2008

Ternary ion-association complex based ion imprinted polymers (IIPs) for trace determination of palladium(II) in environmental samples. Analytica Chimica Acta 570(1): 79-87, 2006

Assessment of molecularly imprinted polymers (MIPs) in the preconcentration of disperse red 73 dye prior to photoelectrocatalytic treatment. Environmental Science and Pollution Research International (): -, 2016

Amperometric determination of chloroguaiacol at submicromolar levels after on-line preconcentration with molecularly imprinted polymers. Talanta 69(1): 259-266, 2008

Molecularly imprinted polymers for on-line clean up and preconcentration of chloramphenicol prior to its voltammetric determination. Analytical and Bioanalytical Chemistry 376(1): 18-25, 2003

Combination of separation/preconcentration based on nanoscale TiO2 and FAAS for the simultaneous determination of Cr(III)/Cr(VI) in water. Guang Pu Xue Yu Guang Pu Fen Xi 27(5): 1018-1020, 2007

Sensitive Determination of Uranium in Natural Waters Using UV-Vis Spectrometry After Preconcentration by Ion-Imprinted Polymer-Ternary Complexes. Journal of Aoac International 99(4): 1043-1048, 2016

Novel Hg2+-imprinted polymers based on thymine-Hg2+-thymine interaction for highly selective preconcentration of Hg2+ in water samples. Journal of Hazardous Materials 237-238: 347-354, 2013

Evaluation of ion imprinted polymers for the solid phase extraction and electrothermal atomic absorption spectrometric determination of palladium in environmental samples. International Journal of Environmental Analytical Chemistry 93(5): 483-498, 2013

Double water compatible molecularly imprinted polymers applied as solid-phase extraction sorbent for selective preconcentration and determination of triazines in complicated water samples. Journal of Chromatography. A 1350: 23-29, 2014

Automated on-line separation preconcentration system for palladium determination by graphite furnace atomic absorption spectrometry and its application to palladium determination in environmental and food samples. Talanta 70(5): 979-983, 2008

Imprinted polymeric materials. Insight into the nature of prepolymerization complexes of quercetin imprinted polymers. Analytical Chemistry 78(17): 6187-6190, 2006