+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Buttonhole cannulation in hemodialysis: improved outcomes and increased expense--is it worth it?



Buttonhole cannulation in hemodialysis: improved outcomes and increased expense--is it worth it?



Cannt Journal 20(1): 29-37



Access to an adequate blood flow is a requirement for successful hemodialysis (HD). This often means repeated cannulation of an arteriovenous fistula (AVF), which can lead to damage that needs repair and revision. The Buttonhole (BH) method offers a successful cannulation with minimal damage. A prospective cohort research study was initiated in two HD units in St. John's, Newfoundland and Labrador, to assess the effects of cannulating AVFs using the BH technique from the patient and nurse perspective. Twenty-five nurses and 29 patients completed questionnaires at four times throughout the three-month study period, rating their confidence levels about BH cannulation issues. Patients also provided information on the pain of the cannulation and the frequency of cannulation complications. Nurses documented data on arterial and venous pressures, and hemostasis times. Patient charts were also reviewed for complications requiring extensive interventions such as AVF repair or Central Line Catheter (CVC) placement. The cost of providing the BH cannulation was also examined. At the end of the study, it was noted that cannulation pain was statistically reduced with both the arterial (p = .002) and venous (p = .010) needles, and vessel pressures and hemostasis times were decreased slightly or stayed the same throughout the study. The frequency of access infections, however, increased, although not significantly. Using a 10-point Likert scale in which a score of > or = 8 indicates a high level of confidence, 77.5% of nurses and 73.9% of patients reported a high level of confidence in the nurses' abilities to use the BH technique effectively. In terms of expense, no significant changes were noted in frequency of procedures required for AVF repair with the BH cannulation, although an increase of approximately $358.80 per patient per year for BH supplies was noted. BH cannulation did provide significant improvements. However, the increase in infection rate was an issue of concern. The additional cost of the BH procedure should be weighed against the positive outcomes realized.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 051882060

Download citation: RISBibTeXText

PMID: 20426358


Related references

Buttonhole cannulation in adult patients on hemodialysis: an increased risk of infection?. Nephrology Nursing Journal 37(5): 491-8 555; Quiz 499, 2010

Buttonhole cannulation and clinical outcomes in a home hemodialysis cohort and systematic review. Clinical Journal of the American Society of Nephrology 9(1): 110-119, 2014

Effect of buttonhole cannulation with a polycarbonate PEG on in-center hemodialysis fistula outcomes: a randomized controlled trial. American Journal of Kidney Diseases 62(1): 81-88, 2013

Infection Rates Following Buttonhole Cannulation in Hemodialysis Patients. Therapeutic Apheresis and Dialysis 20(5): 476-482, 2016

Increased return of spontaneous circulation at the expense of neurologic outcomes: Is prehospital epinephrine for out-of-hospital cardiac arrest really worth it?. Journal of Critical Care 30(6): 1376-1381, 2015

The Impact of Buttonhole Cannulation on Patients and Staff in Hemodialysis Facilities. Contributions to Nephrology 186: 13-20, 2015

Clinical effects of buttonhole cannulation method on hemodialysis patients. Hemodialysis International. International Symposium on Home Hemodialysis 17(2): 294-299, 2013

The effect of buttonhole cannulation vs. rope-ladder technique on hemodialysis access patency. Seminars in Dialysis 27(2): 210-216, 2014

Arteriovenous fistula survival with buttonhole (constant site) cannulation for hemodialysis access. Asaio Journal 60(1): 95-98, 2014

Bacteriology of the Buttonhole Cannulation Tract in Hemodialysis Patients: A Prospective Cohort Study. American Journal of Kidney Diseases 72(2): 234-242, 2018

Use of the BioHole™ device for the creation of tunnel tracks for buttonhole cannulation of fistula for hemodialysis. Hemodialysis International. International Symposium on Home Hemodialysis 15(2): 243-249, 2011

A simple method to create buttonhole cannulation tracks in a busy hemodialysis unit. Hemodialysis International. International Symposium on Home Hemodialysis 14(1): 94-95, 2010

Subscapular abscess associated with buttonhole cannulation technique of arteriovenous fistula for hemodialysis access. Journal of Vascular Access 18(2): E18-E19, 2017

Hemodialysis patients' experience with and attitudes toward the buttonhole technique for arteriovenous fistula cannulation. Clinical Nephrology 74(5): 346-350, 2010

Buttonhole versus rope-ladder cannulation of arteriovenous fistulas for hemodialysis: a systematic review. American Journal of Kidney Diseases 64(6): 918-936, 2014