+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Characteristics of primary and late latent syphilis cases which were initially non-reactive with the rapid plasma reagin as the screening test



Characteristics of primary and late latent syphilis cases which were initially non-reactive with the rapid plasma reagin as the screening test



International Journal of Std and Aids 19(7): 464-468



The aim of the study was to determine the characteristics of primary and late latent syphilis cases that were non-reactive on initial screening by rapid plasma reagin (RPR) but reactive by treponemal tests. RPR test results of all primary and late latent syphilis cases in the province of Alberta, Canada during 1980-2001 were compiled. The proportion of syphilis cases that were non-reactive by RPR testing was compared with reactive cases. Multiple logistic regression was used to identify factors associated with non-reactive RPR results. Among primary syphilis cases, 224 (26%) were non-reactive on initial RPR and were compared with 639 reactive primary cases. Independent factors associated with a non-reactive result were male gender (odds ratio, [OR] = 1.99 [1.22-3.26]), Caucasian ethnicity (OR = 1.77 [1.20-2.61]) and diagnosis during the 1980-1986 syphilis outbreak period in Alberta (OR = 3.13 [1.45-6.74]). Of the late latent cases, 512 (39%) were non-reactive by RPR and 791 were reactive. A non-reactive test for late latent cases was associated with male gender (OR = 2.91 [2.15-3.94]), Canadian Aboriginal (OR = 2.91 [1.59-5.32]), Caucasian (OR = 1.87 [1.35-2.58]), black ethnicity (OR = 1.76 [1.28-2.42]) and diagnosis during the 1980-1986 Alberta syphilis outbreak (OR = 1.67 [1.29-2.16]). RPR testing alone is insufficient to diagnose primary and late latent infections under certain conditions and patient characteristics. Case detection was lower for late latent syphilis when compared with primary syphilis based on the properties of the RPR. Further studies are needed to inform the optimal use of the RPR test in laboratory testing algorithms for the diagnosis of syphilis and to determine the cost effectiveness of better screening tests for syphilis.

(PDF emailed within 0-6 h: $19.90)

Accession: 052024446

Download citation: RISBibTeXText

PMID: 18574118

DOI: 10.1258/ijsa.2007.007302


Related references

Characteristics of patients with primary and late latent syphilis patients who were initially non-reactive to the rapid plasma reagin test. Japanese Journal of Infectious Diseases 66(1): 36-40, 2015

Comparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis. Journal of Clinical Microbiology 17(2): 249-254, 1983

Comparison of the diagnostic accuracy of a rapid immunochromatographic test and the rapid plasma reagin test for antenatal syphilis screening in Mozambique. Bulletin of the World Health Organization 84(2): 97-104, 2006

Predictive value of past and current screening tests for syphilis in blood donors: Changing from a rapid plasma reagin test to an automated specific treponemal test for screening. Transfusion 39(2): 206-211, 1999

The rapid plasma reagin (circle) card test: a screening test for syphilis. Medical Journal of Australia 1(15): 737-739, 1973

Evaluation of a new rapid plasma reagin card test as a screening test for syphilis. Journal of Clinical Microbiology 16(2): 286-290, 1982

Evaluation of NCS rapid plasma reagin card test, a new screening kit for syphilis. Journal of Clinical Microbiology 27(1): 188-189, 1989

Evaluation of the american dade rapid plasma reagin card test as a screening test for syphilis. Abstracts of the Annual Meeting of the American Society for Microbiology 82: ABSTRACT C25, 1982

Comparison of a rapid plasma reagin card test and the unheated serum reagin test for antibodies to syphilis. Abstracts of the General Meeting of the American Society for Microbiology 96(0): 300, 1996

Improving the screening of blood donors with syphilis rapid diagnostic test (RDT) and rapid plasma reagin (RPR) in low- and middle-income countries (LMIC). Transfusion Medicine 27(1): 52-59, 2016

Instant syphilis screening; evaluation of the rapid plasma reagin teardrop card test. Texas Medicine 63(1): 46-48, 1967

Evaluation of the rapid plasma reagin teardrop card test for screening of syphilis in field conditions. Sexually Transmitted Diseases 20(4): 194-197, 1993

Performance of the rapid plasma reagin and the rapid syphilis screening tests in the diagnosis of syphilis in field conditions in rural Africa. Sexually Transmitted Infections 78(4): 282-285, 2002

Comparison of CAPTIA syphilis G enzyme immunoassay with rapid plasma reagin test for detection of syphilis. Journal of Clinical Microbiology 33(7): 1829-1831, 1995

Human Immunodeficiency Virus-Infected Man With Acute Visual Impairment and Panuveitis Due to Syphilis Despite Initially Negative Rapid Plasma Reagin. Sexually Transmitted Diseases 43(11): 709, 2018