+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Characterization of optically stimulated luminescence dosemeters to measure organ doses in diagnostic radiology



Characterization of optically stimulated luminescence dosemeters to measure organ doses in diagnostic radiology



Dento Maxillo Facial Radiology 41(3): 211-216



The aim of this study was to assess the characteristics of an optically stimulated luminescence dosemeter (OSLD) for use in diagnostic radiology and to apply the OSLD in measuring the organ doses by panoramic radiography. The dose linearity, energy dependency and angular dependency of aluminium oxide-based OSLDs were examined using an X-ray generator to simulate various exposure settings in diagnostic radiology. The organ doses were then measured by inserting the dosemeters into an anthropomorphic phantom while using three panoramic machines. The dosemeters demonstrated consistent dose linearity (coefficient of variation<1.5%) and no significant energy dependency (coefficient of variation<1.5%) under the applied exposure conditions. They also exhibited negligible angular dependency (≤ 10%). The organ doses of the X-ray as a result of panoramic imaging by three machines were calculated using the dosemeters. OSLDs can be utilized to measure the organ doses in diagnostic radiology. The availability of these dosemeters in strip form proves to be reliably advantageous.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 052035316

Download citation: RISBibTeXText

PMID: 22116136

DOI: 10.1259/dmfr/98708146


Related references

Comparison Of Surface Doses From Indirect And Direct Digital Radiography Using Optically Stimulated Luminescence Dosemeters. Radiation Protection Dosimetry: 1-7, 2017

Performance of optically stimulated luminescence Al₂O₃ dosimeter for low doses of diagnostic energy X-rays. Applied Radiation and Isotopes 69(10): 1486-1489, 2011

Independent evaluation of optically stimulated luminescence (OSL) 'dot' dosemeters for environmental monitoring. Radiation Protection Dosimetry 143(1): 27-32, 2011

Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence. Radiation Protection Dosimetry 140(3): 294-299, 2010

Assessment Of Diagnostic Multileaf Collimator For Cephalometric Exposure Reduction Using Optically Stimulated Luminescent Dosemeters. Radiation Protection Dosimetry (): -, 2016

An optically stimulated luminescence system to measure dose profiles in x-ray computed tomography. Physics in Medicine and Biology 54(20): 6337-6352, 2010

Use of low temperature methods with optically stimulated luminescence for measuring ionizing radiation doses. Medycyna Pracy 47(3): 293-302, 1996

Dating fluvial sediments by optically stimulated luminescence; selection of equivalent doses for age calculation. Quaternary Science Reviews 22(10-13): 1123-1129, 2003

Measurement of equivalent doses in quartz from contemporary water-lain sediments using optically stimulated luminescence. Quaternary Science Reviews: , Pages 365-371. 1995., 1995

Application of optically stimulated luminescence technique to evaluate simultaneously accumulated and single doses with the same dosimeter. Radiation Physics and Chemistry 95: 134-136, 2014

Application of optically stimulated luminescence to the dosimetry of recent radiation events involving low total absorbed doses. Health Physics 65(4): 396-404, 1993

Organ and effective dose evaluation in diagnostic radiology based on in-phantom dose measurements with novel photodiode-dosemeters. Radiation Protection Dosimetry 118(4): 421-430, 2006

SU-E-T-87: The Effect of Bleaching Wavelengths on the Regeneration of the Optically Stimulated Luminescence Signal of NanoDot Dosimeters Pre-Exposed to High-Doses. Medical Physics 39(6part11): 3722, 2012

An assessment of cumulative external doses from Chernobyl fallout for a forested area in Russia using the optically stimulated luminescence from quartz inclusions in bricks. Journal of Environmental Radioactivity 99(7): 1154-1164, 2008

Organ doses in diagnostic radiology. Health Physics 31(6): 557-558, 1976