+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Clinical usefulness of a newly developed body surface navigation and monitoring system in radiotherapy



Clinical usefulness of a newly developed body surface navigation and monitoring system in radiotherapy



Journal of Applied Clinical Medical Physics 12(2): 3400



In radiotherapy, setup precision has great influence on the therapeutic effect. In addition, body movements during the irradiation and physical alternations during the treatment period might cause deviation from the planned irradiation dosage distribution. Both of these factors could undesirably influence the dose absorbed by the target. In order to solve these problems, we developed the "body surface navigation and monitoring system" (hereafter referred to as "Navi-system"). The purpose of this study is to review the precision of the Navi-system as well as its usefulness in clinical radiotherapy. The Navi-system consists of a LED projector, a CCD camera, and a personal computer (PC). The LED projector projects 19 stripes on the patient's body and the CCD camera captures these stripes. The processed image of these stripes in color can be displayed on the PC monitor along with the patient's body surface image, and the digitalized results can be also displayed on the same monitor. The Navi-system calculates the height of the body contour and the transverse height centroid for the 19 levels and compares them with the reference data to display the results on the monitor on a real-time basis. These results are always replaced with new data after they are used for display; so, if the results need to be recorded, such recording commands should be given to the computer. 1) Evaluating the accuracy of the body surface height measurement: from the relationship between actual height changes and calculated height changes with torso surface by the Navi-system, for the height changes from 0.0 mm to ± 10.0mm, the changes show the underestimation of 1.0-1.5 mm and for ± 11.0mm to ± 20.0 mm, the underestimation of 1.5-3.0 mm. 2) Evaluating the accuracy of the transverse height centroid measurement: displacement of the inclined flat panel to the right by 5.0 mm, 10.0 mm, 15.0 mm and 20.0 mm showed the transverse height centroid calculated by the Navi-system for 0.024 ± 0.007 line/pair (mean ± SD), 0.045 ± 0.006 line/pair, 0.066 ± 0.006 line/pair and 0.089 ± 0.007 line/pair, respectively. Also, displacement of the inclined flat panel to the left by 5.0 mm, 10.0 mm, 15.0mm and 20.0 mm showed the transverse height centroid calculated by the Navi-system for 0.015 ± 0.007 line/pair (mean ± SD), 0.034 ± 0.007 line/pair, 0.053 ± 0.008 line/pair and 0.071 ± 0.007 line/pair, respectively. 3) Clinical usefulness of the Navi-system: on using the Navi-system, the frequency of radiotherapy replanning increased from 5.2% to 21.8%, especially in pelvic or abdominal irradiation. We developed a new navigation system for the purpose of compensating for the weakness of MVCT, CBCT and other systems, as well as for having a screening function. This Navi-system can monitor the patient continuously and measure change in height of the patient's body surface from the basic plane, in real time. It can also show the results both qualitatively and quantitatively on the PC monitor.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 052135031

Download citation: RISBibTeXText

PMID: 21587188


Related references

Application of a newly developed visual navigation system in humans. First results. Minimally Invasive Neurosurgery 48(2): 67-72, 2005

Accurate and continuous geophysical navigation control with newly developed radio system. Pages 472-474:, 1978

Comparison of the newly developed MYCOACID system with mycobacteria growth indicator tube (MGIT) and newly developed 2% Ogawa medium (S) for recovery of mycobacteria in clinical specimens. Kekkaku 76(12): 729-739, 2002

An Analysis of the Characteristics and Improved Use of Newly Developed CT-based Navigation System in Total Hip Arthroplasty. Acta Medica Okayama 71(4): 279-289, 2018

Usefulness of the newly developed transtelephonic electrocardiogram and computer-supported response system. Journal of Cardiology 27(4): 211-217, 1996

Tumor imaging using Tc(V)-99m dimercaptosuccinic acid, a newly developed radiopharmaceutical: its clinical usefulness. Kaku Igaku. Japanese Journal of Nuclear Medicine 22(11): 1653-1660, 1985

Tumor imaging using technetium v 99m dimercaptosuccinic acid a newly developed radiopharmaceutical clinical usefulness. Kaku Igaku 22(11): 1653-1660, 1985

Evaluation of clinical usefulness of lipoprotein in ischemic heart diseases using a newly developed ELISA. Clinical Chemistry 48(6 Suppl.): A107, 2002

Newly developed equipment for analyzing body surface isopotential distribution map. Nihon Rinsho. Japanese Journal of Clinical Medicine 39(1): 223-225, 1981

Quantification of bone mineral in the vertebral body and whole body skeleton with a newly developed dual energy X-ray absorptiometric system using a multi-detector array. Kawasaki Medical Journal 19(3-4): 65-76, 1993 ( ), 1994

Clinical experiences with microwave hyperthermia by newly developed small applicators in combination with radiotherapy. Nihon Igaku Hoshasen Gakkai Zasshi. Nippon Acta Radiologica 45(5): 711-716, 1985

Clinical usefulness of newly developed peripheral nerve blocking for the treatment of facial spasm and electro physiological study of its mechanism 1. clinical study. Acta Scholae Medicinalis Universitatis in Gifu 28(1): 54-67, 1980

Newly developed circulating blood volume-monitoring system and its clinical application for measuring changes in blood volume during hemofiltration. Artificial Organs 10(6): 452-459, 1986

Clinical impact of a newly developed capsule endoscope: usefulness of a real-time image viewer for gastric transit abnormality. Journal of Gastroenterology 43(3): 186-192, 2008

3D Dynamic Body Surface Sensing and Ct-Body Matching: A Tool for Patient Set-Up and Monitoring in Radiotherapy. Computer Aided Surgery 5(4): 234-245, 2000