+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Comparative of coopdech bronchial blocker and double-lumen tube on one lung ventilation in children



Comparative of coopdech bronchial blocker and double-lumen tube on one lung ventilation in children



Zhonghua Yi Xue Za Zhi 94(21): 1651-1653



To compare the application of Coopdech bronchial blocker and double lumen bronchial tube during one lung ventilation in children. Forty children undergoing one lung ventilation for thoracic surgery at Shantou Central Hospital from January 2012 to June 2013, approved by hospital ethics committee, were randomized into Coopdech bronchial blocker group (group A) and double-lumen tube group (group B). Anesthetic management and lung isolation were performed according to a standardized protocol. Two groups of children with the intubation time, intubation success rate, collapse score, the frequency of postoperative hoarseness were recorded. Before and after one lung ventilation in patients of the two groups of PaCO₂, PaO₂ and airway pressure (PAW) changes were recorded. The intubation time in A was longer than those of group B ((224 ± 72)vs(165 ± 46) s, P < 0.05), the success rate of intubation(100% vs 85%, P < 0.05), collapse score in A group was higher than in group B (95% vs 75%, P < 0.05) , Sore throat hoarseness occurred after operation in A group was lower than in B group (10% vs 35%, P < 0.05) , PaO₂ was higher in group A after one lung ventilation for 30 min ((206 ± 58)vs(148 ± 63) mmHg, P < 0.05), PaCO₂ and PAW were lower than group B ((36 ± 4) vs (45 ± 7) mmHg;(21.6 ± 3.2)vs(29.3 ± 5.5) cm H₂O, P < 0.05). The Coodech bronchial blocker provided effective surgical exposure with less throat injuries, higher intubation success rate, lower airway pressure in children during video-assisted thoracoscopic surgery.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 052215111

Download citation: RISBibTeXText

PMID: 25152290


Related references

Is there a better tube for one lung ventilation? Comparison of the modified bronchocath double-lumen tube vs single-lumen tube with enclosed bronchial blocker. Anesthesiology 85(3A): A424, 1996

Bronchial blocker compared to double-lumen tube for one-lung ventilation during thoracoscopy. Acta Anaesthesiologica Scandinavica 45(2): 250-254, 2001

Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker. Anesthesia and Analgesia 86(4): 696-700, 1998

Data Interpretation on the Use of Double-Lumen Tube (DLT) Versus Bronchial Blocker (BB) for One-Lung Ventilation. Journal of Cardiothoracic and Vascular Anesthesia 31(1): E2, 2017

GW25-e0586 Double-lumen endotracheal tube versus bronchial blocker in one lung ventilation. Journal of the American College of Cardiology 64(16): C240-C241, 2014

Selective lobar blockade with a Coopdech blocker combined with a double-lumen endotracheal tube for lung metastases resection by laser. Revista Brasileira de Anestesiologia 68(2): 200-204, 2017

Bronchial Blocker Versus Left Double-Lumen Endotracheal Tube for One-Lung Ventilation in Right Video-Assisted Thoracoscopic Surgery. Journal of Cardiothoracic and Vascular Anesthesia 32(1): 297-301, 2018

The use of a bronchial blocker compared with a double-lumen tube for single-lung ventilation during minimally invasive direct coronary artery bypass surgery. Journal of Cardiothoracic and Vascular Anesthesia 16(4): 452-455, 2002

Lung isolation during port-access cardiac surgery: double-lumen endotracheal tube versus single-lumen endotracheal tube with a bronchial blocker. Journal of Cardiothoracic and Vascular Anesthesia 17(6): 725-727, 2003

Disconnection technique with a bronchial blocker for improving lung deflation: a comparison with a double-lumen tube and bronchial blocker without disconnection. Journal of Cardiothoracic and Vascular Anesthesia 28(4): 904-907, 2014

Accidental fracture of the tip of the Coopdech bronchial blocker during insertion for one lung ventilation. Canadian Journal of Anaesthesia 57(4): 350-354, 2010

One-lung ventilation using a new original connector: with a bronchial blocker and a single lumen tracheal tube. Masui. Japanese Journal of Anesthesiology 52(2): 191-194, 2003

Effects of selective left lower lobar blockade by Coopdech endobronchial blocker tube on intrapulmonary shunt and arterial oxygenation: a comparison with double-lumen endobronchial tube. Nan Fang Yi Ke Da Xue Xue Bao 29(11): 2244-2247, 2009

Airway ventilation pressures during bronchoscopy, bronchial blocker, and double-lumen endotracheal tube use: an in vitro study. Journal of Cardiothoracic and Vascular Anesthesia 28(4): 873-879, 2014

C-Mac guided bronchial blocker (COOPDECH™) insertion for one lung ventilation in an adolescent with difficult airway. Journal of Anaesthesiology Clinical Pharmacology 30(4): 591-592, 2014